Buffalo NBB3 Скачать руководство пользователя страница 5

IS 619   ECN 3949

 

Page 5 of 10 

 

 

 
 

OPERATING INSTRUCTIONS

 

 
 
 
                          

                             

A

B

C

D

E

F

G

 

 
 
 
 
 

Fig 1 

 

Only qualified or trained personnel should use this appliance. 
 

First Use 

 
Switch on the water and electricity supplies.  Leave the boiler to fill for 30 minutes. 
 
Drain off approximately 5 litres of water to remove any loose carbon particles from 
the filter. 
 
 
 

Содержание NBB3

Страница 1: ...ill Water Boilers NBB3 AND NBB3F Please make a note of your product details for future use Date Purchased _________________________ Model Number __________________________ Serial Number ______________...

Страница 2: ...tee 10 IMPORTANT INFORMATION Read these instructions carefully before using this product paying particular attention to all sections that carry warning symbols caution symbols and notices Ensure that...

Страница 3: ...nd clean the appliance before use During operation parts may become hot avoid accidental contact Disconnect this appliance before servicing maintenance or cleaning TECHNICAL DATA Model Height mm Width...

Страница 4: ...odel Power kW Ambient temperature Deg C Water inlet pressure bar Water inlet pressure kPa NBB3 NBB3F 3 0 5 to 30 1 to 8 100 to 800 Electrical supply The units are supplied with a 13 amp plug Water sup...

Страница 5: ...F G Fig 1 Only qualified or trained personnel should use this appliance First Use Switch on the water and electricity supplies Leave the boiler to fill for 30 minutes Drain off approximately 5 litres...

Страница 6: ...rature will be displayed Press the power button to cycle through the values 70 96 Deg C Press the Fn button to select the required value The backlight adjustment screen is displayed next Press the pow...

Страница 7: ...se a water jet or steam cleaner and do not immerse this appliance Clean all panels with warm water and mild detergent do not use abrasive materials Dry with a soft cloth Slide out and empty the drip t...

Страница 8: ...d run the boiler normally for 30 minutes Isolate the boiler and allow the water to cool Remove both outer and tank lids again Inspect the tank and level sensor housings for scale deposits If necessary...

Страница 9: ...AR Scale on level sensors Boiler overfilling Descale Check water inlet valve FILTER NO WATER FAULT SEE MANUAL STANDBY CLEAR Water turned off Inlet hose kinked or blocked Water pressure too high or low...

Страница 10: ...not diminish your statutory or legal rights The guarantee does not cover Accidental damage misuse or use not in accordance with the manufacturer s instructions Consumable items such as filters glass...

Отзывы: