WARNINGS AND PRECAUTIONS

 

 

 

This appliance must be installed, commissioned and serviced by a qualified person 
in accordance with national and local regulations in force in the country of 
installation. 

 
If the supply cord is damaged, it must be replaced by the manufacturer, its service 
agent or similarly qualified person. 
 
Ensure that the plug/socket is accessible at all times. 
 
Strip plastic coating and clean the appliance before use. 
 

During operation parts may become hot - avoid accidental contact. 
 
Disconnect this appliance before servicing, maintenance or cleaning.

 

       

 

TECHNICAL DATA

 

 
 

Model 

Height 

(mm) 

Width (mm)  Depth (mm) 

Weight (kg) 

NBB3 

560 

255 

446 

13 

NBB3F 
 

 
 

CHECK LIST OF ENCLOSURES

 

 
 

Instructions manual 
Drip tray and insert 
Inlet hose with ¾” BSP connection 

 
 

INSTALLATION AND COMMISSIONING

 

 
 

This appliance must be earthed. 

 
An equipotential bonding terminal is provided to allow cross bonding with other 
equipment. 
 

 

If replacing the plug connect the terminals as follows: 

 

Green and Yellow wire   Earth       E 

 

Blue wire                         Neutral   N 

 

Brown wire                      Live        L 

Содержание NBB3

Страница 1: ...ill Water Boilers NBB3 AND NBB3F Please make a note of your product details for future use Date Purchased _________________________ Model Number __________________________ Serial Number ______________...

Страница 2: ...tee 10 IMPORTANT INFORMATION Read these instructions carefully before using this product paying particular attention to all sections that carry warning symbols caution symbols and notices Ensure that...

Страница 3: ...nd clean the appliance before use During operation parts may become hot avoid accidental contact Disconnect this appliance before servicing maintenance or cleaning TECHNICAL DATA Model Height mm Width...

Страница 4: ...odel Power kW Ambient temperature Deg C Water inlet pressure bar Water inlet pressure kPa NBB3 NBB3F 3 0 5 to 30 1 to 8 100 to 800 Electrical supply The units are supplied with a 13 amp plug Water sup...

Страница 5: ...F G Fig 1 Only qualified or trained personnel should use this appliance First Use Switch on the water and electricity supplies Leave the boiler to fill for 30 minutes Drain off approximately 5 litres...

Страница 6: ...rature will be displayed Press the power button to cycle through the values 70 96 Deg C Press the Fn button to select the required value The backlight adjustment screen is displayed next Press the pow...

Страница 7: ...se a water jet or steam cleaner and do not immerse this appliance Clean all panels with warm water and mild detergent do not use abrasive materials Dry with a soft cloth Slide out and empty the drip t...

Страница 8: ...d run the boiler normally for 30 minutes Isolate the boiler and allow the water to cool Remove both outer and tank lids again Inspect the tank and level sensor housings for scale deposits If necessary...

Страница 9: ...AR Scale on level sensors Boiler overfilling Descale Check water inlet valve FILTER NO WATER FAULT SEE MANUAL STANDBY CLEAR Water turned off Inlet hose kinked or blocked Water pressure too high or low...