4
UK
Troubleshooting
Technical Specifications
Electrical Wiring
This appliance is supplied with a 3 pin, moulded, BS1363 plug and lead, with a 13 amp fuse as standard.
The plug is to be connected to a suitable mains socket.
This appliance is wired as follows:
•
Live wire (coloured brown) to terminal marked L
•
Neutral wire (coloured blue) to terminal marked N
•
Earth wire (coloured green/yellow) to terminal marked E
This appliance must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency
disconnection being required they must be readily accessible.
Fault
Probable Cause
Action
The unit is not
working
The unit is not switched on
Check the unit is plugged in correctly and
switched on
Plug and lead are damaged
Call BUFFALO agent or qualified technician
Fuse in the plug has blown
Replace the plug fuse
Power supply
Check power supply
Internal wiring fault
Call BUFFALO agent or qualified technician
Coffee is not
coming from the
filter basket
No water in reservoir
Turn Off and fill reservoir
Coffee is too compact within the
filter
Turn off, loosen coffee within the filter and
resume
Loud noise coming
from appliance
No water in reservoir
Turn Off and fill reservoir
Model
Voltage
Power
Current
Reservoir
Capacity
Weight
Dimensions
h x w x d mm
DN487
230V 50Hz
2.2Kw
9.1A
2.2 litres
5.8kg
455 x 205 x 405