5
UK
Telephone Helpline: 0845 146 2887
4. When the set temperature is reached, the temperature indicator light will turn off.
Note:
• During use, the temperature indicator light will cycle on/off, indicating the
set temperature is being maintained.
• During cooking, the temperature and cooking time can be adjusted at any
time.
5. When the cooking time elapses, the appliance will beep then turn Off.
Overheating protection
This appliance is featured with an overheat protection. Should the temperature exceed safe levels the
appliance will automatically cut off power.
The thermal Cut-out switch is located on the rear of the appliance. To reset the appliance after a sufficient
cool-down period:
1. Press the small reset switch down until it clicks.
2. The appliance is now reset and can be used as normal.
Cleaning, Care & Maintenance
•
Warning: Always turn off and disconnect the appliance from the power supply before
cleaning. Always allow the appliance to cool before cleaning.
• Clean the interior of the appliance as often as possible.
• Do not use abrasive cleaning agents. These can leave harmful residues.
• For stains on the interior walls, wipe with a cloth damped with some mild soapy solution. Ensure no
moisture enters the inside of the cabinet.
• Always wipe dry after cleaning.
• A BUFFALO dealer or qualified technician should carry out repairs if required.
Cleaning the grill shelf and baking tray
• After use, remove the parts from the appliance for cleaning.
• Clean using warm, soapy water. Rinse thoroughly and dry well.
• Re-locate into the appliance.
Troubleshooting
If your BUFFALO appliance develops a fault, please check the following table before making a call to the
Helpline.
Fault
Probable Cause
Solution
The unit is not
working
The unit is not switched on
Check the unit is plugged in correctly and
switched on
Plug and lead are damaged
Call BUFFALO agent or qualified Technician
Fuse in the plug has blown
Replace the plug fuse
Power supply
Check power supply
Internal wiring fault
Call BUFFALO agent or qualified technician
Overheating protection is activated
Reset the appliance
Unit heats up but
indicator light does
not come on
Bulb has expired
Call BUFFALO agent or qualified technician
DA957_UK_A5_v1_20191210.indb 5