UK
Trouble Shooting
If your BUFFALO product develops a fault, please check the following table before making a call to your
BUFFALO agent.
Fault
Probable Cause
Action Required
The product is not working
The product is not switched on
Check the unit is plugged in correctly and
switched on
Plug and lead are damaged
Call your BUFFALO agent or qualified
electrical technician
Fuse in the plug has blown
Replace the plug fuse
Power supply problem
Check power supply
Internal wiring fault
Call your BUFFALO agent or qualified
electrical technician
Product does reach set temperature
Faulty thermostat
Call your BUFFALO agent or qualified
electrical technician
Faulty element
Call your BUFFALO agent or qualified
electrical technician
The light only comes on when the power is
going to the element so the product can be
hot when this light goes out.
Bulb has failed
Call your BUFFALO agent or qualified
electrical technician
Power indicator light comes on but product
does not heat up
Faulty element
Call your BUFFALO agent or qualified
electrical technician
Faulty thermostat
Call your BUFFALO agent or qualified
electrical technician
Thermostat set incorrectly
Check thermostat setting
Product slow to heat up
Cooking surface not cleaned
Clean cooking surface as instructions
Faulty element
Call your BUFFALO agent or qualified
electrical technician
Technical Specifications
Code
Voltage
Power
Watts
Current
Plate Type
Dimensions
Weight Kgs
Top
Bottom
h x w x d (mm)
CD474
230V 50Hz
1500W
6.5A
Rib
Rib
210 x 290 x 320
14.5kgs
DM902
230V 50Hz
2900W
12.6A
Rib
Rib
210 x 540 x 320
27kgs
DM903
230V 50Hz
2200W
9.5A
Rib
Rib
210 x
380
x 320
19kgs
GJ454
230V 50Hz
1500W
6.5A
Flat
Flat
210 x 290 x 320
16kgs
GJ455
230V 50Hz
2200W
9.5A
Flat
Flat
210 x 380 x 320
21kgs
GJ456
230V 50Hz
2900W
12.6A
Flat
Flat
210 x 540 x 320
29kgs
Electrical Wiring
This appliance is supplied with a 3 pin, moulded, BS1363 plug and lead, with a 13 amp fuse as standard
The plug is to be connected to a suitable mains socket
The appliance is wired as follows:
• Live wire (coloured brown) to terminal marked L
• Neutral wire (coloured blue) to terminal marked N
• Earth wire (coloured green/yellow) to terminal marked E
This appliance must be earthed, using a dedicated earthing circuit
If in doubt, consult a qualified electrician
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being required
they must be readily accessible
Содержание CD474