background image

www.buffalotech.com

User Manual

Gigabit Managed Switch with PoE+

BSL-PS-G2108M

BSL-PS-G2116M

Содержание BSL-PS-G2108M

Страница 1: ...www buffalotech com User Manual Gigabit Managed Switch with PoE BSL PS G2108M BSL PS G2116M...

Страница 2: ...ettings 11 Accessing settings 11 Home 13 Panel Display 13 Main 14 System Info 14 Basic 15 System 15 MAC Address Filtering 16 Flow Control Status 17 Flow Control 18 Admin Account 19 Date and Time 20 Po...

Страница 3: ...46 Save and Restore Settings 47 Reboot 48 Initialize 49 MAC Address Table Port Order 49 MAC Address Table MAC Address Order 50 Statistics 51 Logs 53 Syslog Settings 53 Restore from USB 54 Ping 56 I m...

Страница 4: ...3 Appendix 60 Default Configuration Settings 60 Twisted Pair Cable and Port Specifications 62...

Страница 5: ...hardware reset switch Layer 2 Switching Supports 802 3x flow control and back pressure Throughput 1000M 1488095 pps 100M 148810 pps 10M 14880 pps VLAN support VLAN groups 256 VLAN ID 1 to 4094 IEEE 8...

Страница 6: ...P TLS and EAP MS PEAP Password authentication support PAP MAC authentication support PAP When performing IEEE 802 1X MAC authentication EAPOL Start must be issued from the supplicant to start authenti...

Страница 7: ...dards Supports IEEE 802 3at LLDP If using the BSL PS G2116M a maximum total of 180 W of power can be supplied to all devices If using the BSL PS G2108M a maximum total of 150 W of power can be supplie...

Страница 8: ...Power green On Power is on Off Power is off USB green On USB device inserted Blinking Accessing the USB memory device Off USB device removed Diag green or red On green Normal On red Hardware reset swi...

Страница 9: ...supports AUTO MDIX As the port type at the other end is determined automatically there is no need to make a selection of either a straight cable or a crossover cable However the AUTO MDIX function is...

Страница 10: ...table for each VLAN It differs from SVL which retains a shared MAC address table for the entire device Be sure you understand how IVL works before you create a VLAN with the switch Differences betwee...

Страница 11: ...connecting power cables or worrying about power outlet locations PoE compatible wireless LAN PoE compatible adapter Wireless LAN access point BS Series PoE compatible switch PoE compatible IP phone T...

Страница 12: ...twork Use a Web browser such as Internet Explorer 7 0 or later to display Settings Accessing settings 1 Connect the administrator computer 2 Download the Business Switch Configuration Tool from Buffal...

Страница 13: ...ress screen appears select Get IP address from DHCP or set the IP address manually and click Next 8 Log in to the switch configuration interface Enter admin for the username and password for the passw...

Страница 14: ...he system information is displayed on the right Click the links in the menu tree to move to other menus and display setup parameters and statistics Panel Display The status of each port link status li...

Страница 15: ...Info Parameter Meaning Product Name Product name System Name Name of the switch IP Address IP address subnet mask and default gateway of the switch Firmware Firmware version of the switch Boot Code B...

Страница 16: ...anumeric characters hyphens and underscores _ IP Address Set an IP address of the switch Subnet Mask Set a subnet mask of the switch Default Gateway Set the default gateway IP address DHCP This enable...

Страница 17: ...orts where a MAC address is registered only frames that have the registered MAC address as the source MAC address can pass through and other frames are blocked Frame filtering is performed during inpu...

Страница 18: ...lays whether the port is enabled or disabled Flow Control Displays whether flow control is enabled or disabled EEE Displays whether low power idling IEEE 802 3az is enabled or disabled Link Displays w...

Страница 19: ...ns and underscores _ Allow Enable or disable the selected port Flow Control Enable or disable flow control EEE Enable or disable low power idling IEEE 802 3az Mode Specify the rate and duplex mode Jum...

Страница 20: ...e name of the Administrator account is admin Password This is the password for logging in to the switch It may contain up to 8 alphanumeric characters hyphens and underscores _ Confirm Password Enter...

Страница 21: ...er you are using to perform setup This takes a few seconds to set Enable SNTP This is selected to use the SNTP server Set the SNTP Server IP Refresh Interval and Time Zone If you do not use SNTP the c...

Страница 22: ...the power currently being used Available This indicates the difference between the maximum power and power usage PoE This indicates On Off for the PoE Status This indicates the PoE supply status Powe...

Страница 23: ...e This indicates the profile 1 to 4 that was set in the power saving profiler PoE This enables or disables the PoE Priority This sets the priority of the PoE supply If the maximum total power supply i...

Страница 24: ...p to 15 4 W max at LLDP packets are sent at 30 second intervals from ports set to use 802 3at If the PD supports LLDP power is dynamically adjusted If the connected PD is class 0 to 3 15 4 W of power...

Страница 25: ...ower saving profiler The power saving profiler is a function used to dynamically or manually switch to different PoE settings This function can be set in the Web Admin interface only It cannot be set...

Страница 26: ...hedule Click to open the timetable editing screen Schedule Weekly This displays the schedule by the day of the week Daily This displays the schedule by the day To set to automatic profile switching mo...

Страница 27: ...to time frames not having any specific profile for the date or day of the week Profile This is used to set the profile name Initialization Click to initialize the profile that was selected in Choose p...

Страница 28: ...om 6 00 to 30 00 is treated as one day The time frame from 24 00 to 30 00 is equivalent to 0 00 to 6 00 of the next day Day of week Specify the day of the week that is added to the timetable This is e...

Страница 29: ...le from a different day is selected Schedule This displays the schedule list that was set Turn Off LEDs This function is used to set the LEDs on and off This setting can be managed in the profile of t...

Страница 30: ...Chapter 2 Configuration 29 Advanced VLANs These settings are used to view the current VLAN settings and create new VLANs Advanced VLANs VLANs...

Страница 31: ...member Not a Member Indicates that the port as not been assigned as a member Restore Reloads the current VLAN settings Clear Clears the settings shown Privacy Separator Enable or disable Privacy Separ...

Страница 32: ...he configuration interface If the Privacy Separator is enabled all existing VLANs are deleted and it is no longer possible to create or edit VLANs All trunking settings are also deleted and disabled P...

Страница 33: ...ority level cannot be sent ahead of this in the queue WRR This performs queue scheduling based on a weighted round robin Data is sent according to the ratio of output of data packets specified in each...

Страница 34: ...priority levels Advanced QoS QoS Mapping Parameter Meaning Port Priority Queue Sets the priority level for each port CoS Mapping Queue Set the priority queue for CoS 0 to 7 ToS Mapping Queue Set the...

Страница 35: ...tus of the authentication server and port authentication Advanced Authentication Status Parameter Meaning Status This displays the authentication status If IEEE 802 1X authentication is enabled this i...

Страница 36: ...ver may contain up to 20 alphanumeric characters hyphens and underscores _ Reset Timer Sets the time until the next authentication is required Range 1 to 65535 Termination Action This is selected to a...

Страница 37: ...802 1X Port 802 1X authentication is performed on a port basis When authentication is completed communication can be performed by all devices connected to the port 802 1X MAC 802 1X authentication is...

Страница 38: ...eforehand at the RADIUS server MAC authentication is not started two consecutive times for the same MAC address If MAC authentication fails either disconnect and reconnect the LAN cable or try authent...

Страница 39: ...assword authentication page Login Shortcut Click Create to create a shortcut of the password authentication page Port number 80 cannot be set because it is already used in the Web settings Image This...

Страница 40: ...on page The connection address of the Web authentication page is shown below http switch IP address Port number Example Default setting http 192 168 1 254 8080 Only ports where Web authentication was...

Страница 41: ...orts that are the trunk members LACP packets are not sent or received The maximum number of ports where port trunking can be set is shown below Product Name LACP Trunk Manual BSL PS G2108M 4 ports 4 p...

Страница 42: ...temporarily forms a loop and the buzzer may sound due to the loop prevention function Operation is performed normally after the LACP or trunk is established Traffic Storm Control These settings are f...

Страница 43: ...t and DLF destination lookup failure unicasts Set a the rate limit to a value with room considering the number of frames normally used Mirrored Ports These settings are for monitoring traffic copying...

Страница 44: ...43 BPDU Forwarding These settings are used to configure BPDU Advanced BPDU Forwarding Parameter Meaning BPDU Forwarding Enable or disable the BPDU packets of Spanning Tree Protocol transmitted BPDU Br...

Страница 45: ...44 Chapter 2 Configuration Loop Prevention Configure loop prevention settings here Advanced Loop Prevention...

Страница 46: ...Thrashing This enables the MAC thrashing system of the loop detection function A loop is recognized if the number of learned MAC addresses of this switch exceeds the preset threshold value in 1 secon...

Страница 47: ...can be performed temporarily while the port is disabled Except when storm control is enabled communication cannot be performed until the loop is removed Automatic Communication is disconnected while...

Страница 48: ...begin the firmware upgrade The only files displayed in the list are those with a rom extension Do not turn off the switch or close the browser during the upgrade Once the upgrade is complete The produ...

Страница 49: ...re and click Restore to restore it When saving to a USB device the extension is automatically set to cfg Do not turn off the device while saving or restoring Once the file is restored The product will...

Страница 50: ...ialize except IP Initializes all settings except the IP address subnet mask and default gateway and reboots the switch Initialize Initializes all settings and reboots the switch Reset Button Enable or...

Страница 51: ...formation Click Clear to clear the table MAC Address Table MAC Address Order This displays the MAC address table in MAC Address order Management MAC Address Table MAC Order Parameter Meaning MAC Addre...

Страница 52: ...eaning Name Name of the port Received Octets Data octets received Received Packets Packets received Sent Octets Data octets sent Sent Packets Packets sent Details Click Details to display detailed inf...

Страница 53: ...ack of system resources Received Packet Errors Packets received that contained errors such as CRC errors Sent Octets Data octets sent Sent Unicast Unicast packets sent Sent Multicast Multicast packets...

Страница 54: ...the type of log message displayed Click Clear to clear the syslog Click and to change pages The correct time must be set using SNTP Settings to display the corect time in the log information Syslog Se...

Страница 55: ...ame Include information on the switch s MAC address and the switch name in the log Type Select the category of log information sent There are four log categories Configuration Authentication Device an...

Страница 56: ...he configuration is changed If enabled the settings file is automatically saved to default cfg and yyyymmdd cfg on the USB device whenever configuration changes are made The latest version is always s...

Страница 57: ...I m here The selected switch will sound a buzzer making it easy to locate Management I m here Parameter Meaning Duration of Beep This sets the duration that the buzzer is sounded when I m here is exec...

Страница 58: ...pter 2 Configuration 57 Support Support This displays Buffalo s website Support Parameter Meaning Support This is a link to Buffalo s website where you can find documentation updated firmware and supp...

Страница 59: ...ications Check that the Ethernet adapter on the connected device is operating properly and that there are no problems with the Ethernet cable Can t access via browser Check that you are connected to a...

Страница 60: ...th the internal power supply unit Access from the Network You can use a Web browser to access and manage the switch from anywhere on the network to which it is connected However you must configure a v...

Страница 61: ...g Flow Control Name Port_ port number Allow On Flow Control Off EEE On Mode Auto Jumbo Frames On Admin Account Username admin Password password Date and Time Date and Time Disable SNTP 1900 Year 1 Mon...

Страница 62: ...runking Disabled Traffic Storm Control Broadcast Unlimited Multicast Unlimited DLF Unlimited Mirroring Mirror 1 Mirror 2 Disabled BPDU Forwarding BPDU Forwarding Disabled Loop Prevention Loop Preventi...

Страница 63: ...rt Specifications In the cables used in 100BASE TX 10BASE T pins 1 and 2 are used for sending data and pins 3 and 6 are used for receiving data The switch supports AUTO MDIX on all ports You can use s...

Страница 64: ...elow Pin number MDIX MDI signal Signal function 1 BI_DA BI_DB Send and receive data A Send and receive data B 2 BI_DA BI_DB Send and receive data A Send and receive data B 3 BI_DB BI_DA Send and recei...

Страница 65: ...fully and securely inserted into the outlet Do not use the product with a power cable that is damaged torn or frayed Do not allow a young child to use this product except under the supervision of an...

Страница 66: ...solvent such as thinner or benzine to clean the product Only use the power cable or AC adapter and signal cables that came with this product Static Electricity Electrostatic discharge commonly referre...

Страница 67: ...ments in places where strong magnetic fields or static electricity may be generated in places where the temperature humidity conditions may produce condensation or exceed the levels specified in the d...

Отзывы: