Item # GEN4000TRI 4000 Surge Watt / 3500 Running Watt Portable Tri Fuel LP Liquid Propane, Gasoline, Natural Gas Generator Manual
15
Step 3 - Ground the Generator
Failure to properly ground this generator can result in electrocution.
Ground this generator by tightening the grounding nut against a grounding wire as previously illustrated in Figure 3. A generally acceptable grounding
wire is a No. 12 AWG (American Wire Gauge) stranded copper wire. The other end of this grounding wire should be connected to a copper or brass
grounding rod that is driven into the earth. Grounding codes can vary by location. Contact a local electrician for information on grounding regulations for
your area.
STARTING THE GENERATOR
STOP!
Before starting this generator, confirm that all the steps in the section titled, “Preparing the Generator for Use,” of this manual have been
correctly completed. If unsure about how to perform any of these steps, call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time for
customer service.
Disconnect all electrical loads from this generator before attempting to start.
Step 1 If using Propane LPG fuel, open fuel supply on the LP tank.
If using NG fuel, open fuel supply on the NG pipe.
If using gasoline, make sure unleaded gasoline fuel has been added to the tank.
Step 2 If using Propane LPG/NG fuel, turn ENGINE SWITCH to ON position, and Petcock to OFF position.
NOTE: Be sure that the carburetor is free of gasoline.
If using gasoline, turn ENGINE SWITCH to ON position and Petcock to ON position, and LPG/NG fuel system to OFF position.
Step 3 Move Choke Lever to CLOSED/START position.
Step 4 For recoil start: Pull the STARTER GRIP slowly until resistance is felt and then pull rapidly. After the engine started, return the STARTER
GRIP gently to prevent damage to the starter or housing. DO NOT allow the starter grip to snap back. Return it slowly by hand.
Step 5 Turn the CHOKE LEVER to OPEN/RUN position.
Choke Lever
The choke is used to provide an enriched fuel mixture when starting a cold engine. It can be opened and closed by operating the choke lever manually.
Push the lever toward CLOSED/START position to enrich the mixture for cold starting