General Information
1
1
General Information
1.1
Tank Packaging and Components
The S120 indirect fired hot water tank is a 32 gal glass
lined steel tank. The tank is fully packaged with a high
density foam insulation and steel jacket panel. A Honey-
well aquastat is standard supplied with the tank.
Additional components supplied with the tank are:
1 125 psi P and T valve
3 3/4“ brass couplings
1 3/4“ brass tee
1 Honeywell L4006 adjustable differential tank aquastat
1 Aquastat mounting bracket and 4 mounting screws
3 Adjustable tank leg leveling bolts
1 Roll of high quality teflon tape
1.2
Tank Placement
Install the tank in a dry, frost free room.
Make sure that the tank is completely drained before
taking the tank out of use. Protect from freezing.
Place the tank on a level floor of sufficient strength.
Observe the recommended clearances as shown in
Fig.1. These dimensions are based on ample access for
installation and maintenance (Fig. 1). Maintain a
minimum clearance of 2“ between hot water piping or
tank surface to combustible surfaces.
Fig. 1
Recommended clearance for installation and
maintenance.
500
400
min. 100
16"
4"
16"