background image

4

 

Taking the heating system out of operation

Logano GC 144 II – 6 720 808 895 (2014/04)

5

4

Taking the heating system out of operation

4.1

Normal system shut-down

▶ Turn ON/OFF switch (emergency shutoff switch) to OFF position. 

This shuts off power to the boiler and all of its components (e.g. 
burner, aquastat).

▶ Close gas shut off-valve.

Fig. 5  

System shut-down

[1]

ON/OFF switch (emergency shut off switch)

4.2

Emergency shut-down procedures

Perform this procedure in case of emergency:
▶ Never put yourself at risk. Your own safety must always take priority.
▶ Shut off main gas supply.
▶ Shut down the heating system using the boiler emergency shutoff 

switch or the corresponding circuit-breaker.

NOTICE: 

System damage due to freezing.

The heating system can freeze up in cold weather if it is 
shut down.

▶ Leave the heating system switched ON constantly as 

much as possible.

▶ Protect the heating system from freezing by draining 

the boiler and water pipes at the lowest point.

1

6 720 

8

04 441-10.1T