6 720 804 891 – 2012/10 EN-US

For the installer

Please read carefully before use.

Operating instructions

Sealed combustion boiler
Logano GA124 SC 

WARNING!

If these instructions are not followed exactly, a fire or explosion may be caused 
with serious property damage or loss of life and serious injury.

Do not store or use gasoline or any 
other flammable vapors or liquids in 
the vicinity of this system or any other 
heating system.

IF A SMELL OF GAS IS DETECTED:

Do not switch on any electrical 
appliances.

Do not operate electrical switches; do 
not use a telephone in the building.

Call gas company immediately from 
outside the building. Follow these 
instructions.

If you cannot reach your gas 
company, call the fire department.

The heating system must only be 
installed and serviced by a qualified 
service company, a qualified service 
or gas supply company.

NOTE! Please keep these instructions for future reference.

Содержание Logano GA124 SC

Страница 1: ...pors or liquids in the vicinity of this system or any other heating system IF A SMELL OF GAS IS DETECTED Do not switch on any electrical appliances Do not operate electrical switches do not use a tele...

Страница 2: ...or The contractor must give detailed instructions on the operation of the heating system Please read these operating instructions carefully 1 3 1 Boiler room WARNING RISK TO LIFE Identifies possible d...

Страница 3: ...ting system The flue system must be inspected and cleaned once a year All parts that show any signs of damage by corrosion or other causes must be replaced The boiler must be serviced by qualified boi...

Страница 4: ...SC only and Aquasmart control Boiler jacket and front panel Boiler block with insulation Burner The automatic ignition and the Aquasmart control monitor and control all electrical components of the bo...

Страница 5: ...ed technician Any attempt to use force or to repair the switch may cause a fire or explosion D Do not operate the unit if any part is under water Contact a qualified customer service technician immedi...

Страница 6: ...re is still any smell of gas including at floor level If there is a gas odor STOP Follow instructions in section B of the safety instructions in Chapter 3 page 5 If there is no sign of a gas odor cont...

Страница 7: ...ckwise to OFF position Do not use force 5 If necessary shut off main gas supply shut off 6 Replace front panel of boiler Flame roll out switch The boiler is equipped with a flame roll out switch If th...

Страница 8: ...2 Emergency shut down Inform your customer of the procedure in case of emergency such as a fire 1 Never put yourself at risk Your own safety must always take priority 2 Shut off main fuel supply valve...

Страница 9: ...Shutting down of the boiler 4 9 We reserve the right to make any changes due to technical modifications Operating instructions Logano GA124 SC special gas fired boiler Issue 2012 10...

Страница 10: ...Notes 10 Operating instructions Logano GA124 SC special gas fired boiler Issue 2012 10 We reserve the right to make any changes due to technical modifications...

Страница 11: ...Notes 11 We reserve the right to make any changes due to technical modifications Operating instructions Logano GA124 SC special gas fired boiler Issue 2012 10...

Страница 12: ...52 1100 Fax 603 965 7581 www buderus us Products manufactured by Bosch Thermotechnik GmbH Sophienstrasse 30 32 D 35576 Wetzlar www buderus com Bosch Thermotechnology Corp reserves the right to make ch...