background image

For your safety

1

2

Operating instructions Logano GA124 SC special gas-fired boiler • Issue 2012/10

We reserve the right to make any changes due to technical modifications.

1

For your safety

The Logano GA124 SC gas-fired boiler is designed and 
manufactured in accordance with in state of the art in 
technology and safety. Particular emphasis is placed on 
ease of operation. We recommend reading and 
following the safety instructions and operating manual 
for safe, economical and environmentally responsible 
operation of the heating system.

1.1

Correct use

The Logano GA124 SC gas-fired boiler is designed to 
heat water using indirect domestic hot water tanks and 
space for heating single or multi family buildings.

1.2

Notes structure

Additional symbols for identification of dangers and user 
instructions. 

1.3

Please observe these safety 
instructions

Improper operation of the boiler may cause property 
damage.

Only use the boiler for the intended purpose and only 
if it is in perfect working order.

Have the heating system installed by a heating 
contractor.

The contractor must give detailed instructions on the 
operation of the heating system.

Please read these operating instructions carefully.

1.3.1 Boiler room

WARNING!

RISK TO LIFE

Identifies possible dangers emanating 
from a product, which might lead to 
serious injury or death if appropriate care 
is not taken. 

CAUTION!

RISK OF INJURY/
SYSTEM DAMAGE

Identifies potentially dangerous situations, 
which might lead to medium or slight 
injuries or to property losses.

USER NOTE

Information on optimum utilization and 
setting of the control(s) plus other useful 
information.

WARNING!

RISK TO LIFE

due to neglecting your own safety in case 
of emergency, such in case of a fire.

Never put yourself at risk. Your own 
safety must always take priority.

CAUTION!

BOILER DAMAGE AND OPERATING 
DEFECTS

due to missing or inadequate openings for 
combustion air and venting of the boiler 
room.

Make sure that inlets and outlets are 
not obstructed or blocked off.

If defects are not corrected 
immediately, the boiler must not be 
operated.

WARNING!

FIRE DANGER

due to flammable material or liquids.

Do not store flammable material or 
liquids in the immediate vicinity of the 
heat generator.

CAUTION!

SYSTEM DAMAGE

through frost.

Make sure that the boiler room is 
protected from freezing.

Содержание Logano GA124 SC

Страница 1: ...pors or liquids in the vicinity of this system or any other heating system IF A SMELL OF GAS IS DETECTED Do not switch on any electrical appliances Do not operate electrical switches do not use a tele...

Страница 2: ...or The contractor must give detailed instructions on the operation of the heating system Please read these operating instructions carefully 1 3 1 Boiler room WARNING RISK TO LIFE Identifies possible d...

Страница 3: ...ting system The flue system must be inspected and cleaned once a year All parts that show any signs of damage by corrosion or other causes must be replaced The boiler must be serviced by qualified boi...

Страница 4: ...SC only and Aquasmart control Boiler jacket and front panel Boiler block with insulation Burner The automatic ignition and the Aquasmart control monitor and control all electrical components of the bo...

Страница 5: ...ed technician Any attempt to use force or to repair the switch may cause a fire or explosion D Do not operate the unit if any part is under water Contact a qualified customer service technician immedi...

Страница 6: ...re is still any smell of gas including at floor level If there is a gas odor STOP Follow instructions in section B of the safety instructions in Chapter 3 page 5 If there is no sign of a gas odor cont...

Страница 7: ...ckwise to OFF position Do not use force 5 If necessary shut off main gas supply shut off 6 Replace front panel of boiler Flame roll out switch The boiler is equipped with a flame roll out switch If th...

Страница 8: ...2 Emergency shut down Inform your customer of the procedure in case of emergency such as a fire 1 Never put yourself at risk Your own safety must always take priority 2 Shut off main fuel supply valve...

Страница 9: ...Shutting down of the boiler 4 9 We reserve the right to make any changes due to technical modifications Operating instructions Logano GA124 SC special gas fired boiler Issue 2012 10...

Страница 10: ...Notes 10 Operating instructions Logano GA124 SC special gas fired boiler Issue 2012 10 We reserve the right to make any changes due to technical modifications...

Страница 11: ...Notes 11 We reserve the right to make any changes due to technical modifications Operating instructions Logano GA124 SC special gas fired boiler Issue 2012 10...

Страница 12: ...52 1100 Fax 603 965 7581 www buderus us Products manufactured by Bosch Thermotechnik GmbH Sophienstrasse 30 32 D 35576 Wetzlar www buderus com Bosch Thermotechnology Corp reserves the right to make ch...

Отзывы: