Extended functions
7
Logamatic 4121, 4122 and 4126 - Subject to technical modifications.
36
7.8
Heating circuits with MEC2 programming unit
During installation, your heating contractor will determine which heating circuits
are to be controlled by the MEC2 programming unit. These heating circuits will
be designated "MEC heat. circ.".
MEC heat. circ.
The following adjustments made at the MEC2 apply all to "MEC heat. circ."
simultaneously:
–
Setting the room temperature
–
Setting the summer/winter time changeover
–
Selecting the operating mode
–
Setting the holiday function
–
Setting the party or pause function
If you have selected an individual heating circuit that is assigned to the MEC2,
and you want to make one of the above adjustments, the fault message
"Setting Not possible. MEC heat. circ. select" will appear.
Select "MEC heat. circ." to program these settings (
Æ
Chapter 7.6).
Individual heating circuits
The following adjustments can only be implemented for each individual heating
circuit separately:
–
Selecting the standard program
–
Modifying the standard program by moving switching points
–
Inserting or deleting switching points
–
Deleting or connecting heating phases
–
Creating a heating, DHW or DHW circulation pump program
If you have selected "MEC heat. circ.", and you want to make one of the
above adjustments, the fault message "Time switch Not possible. Single heat
circ select" will appear.
Enter these settings for each heating circuit separately (
Æ
Chapter 7.6).
Setting
select
MEC heat. circ.
Not possible
Time switch
select
Single heat circ
Not possible