6
Commissioning
PW/P/PR/PNR/PNRZ... – 6 720 817 509 (2017/05)
41
6
Commissioning
Commissioning must be performed by an authorised contractor.
▶ Check the tightness of all connections (
▶ Commission all assemblies and accessories as specified in the
manufacturer's technical documents.
7
Shutdown
▶ If an immersion heater has been installed (accessory), isolate the
buffer cylinder from the power supply.
▶ Switch off the temperature controller at the control unit.
▶ Fully drain the buffer cylinder.
▶ Shut down all assemblies and accessories of the heating system as
specified in the manufacturer's technical documentation.
▶ Open the system drain valve.
▶ For ventilation, open the air vent valve. The air vent valve is located at
the top of the cylinder (
▶ Close the shut-off valves.
▶ Depressurize the heat exchanger.
▶ Drain and blow out the heat exchanger.
To prevent corrosion:
▶ Leave the connector pipes open, so that the interior can dry out well.
8
Environment/disposal
Environmental protection is a key commitment of the Bosch Group.
Quality of products, efficiency and environmental protection are equally
important objectives for us. All legislation pertaining to the
environmental protection is strictly observed. To protect the
environment we use the best possible technology and materials, subject
to economic considerations.
Packaging
Where packaging is concerned, we participate in country-specific
recycling systems that ensure optimum recycling. All of our packaging
materials are environmentally compatible and can be recycled.
Used appliances
Old appliances contain materials that should be recycled.
The relevant assemblies are easy to separate and all plastics are
identified. In this way the individual assemblies can be easily sorted and
directed to recycling or disposal.
9
Service work
With buffer cylinders, apart from visual checks, no particular
maintenance or cleaning work is necessary.
▶ Check all connections externally for leaks once a year.
▶ In the event of a fault, contact an approved contractor or the
customer service.
NOTICE:
Risk of system damage from excessive pressure.
▶ Observe the maximum operating pressure (
DANGER:
Risk of scalding from hot water!
▶ Allow the buffer cylinder time to cool down sufficiently
after being shut down.
NOTICE:
Cylinder damage from frost!
If there is a risk of frost when you are away from home,
we recommend the following:
▶ Leave the buffer cylinder operational.
or
▶ Take the buffer cylinder out of operation and drain it.
Содержание 7735500817
Страница 71: ...9 Onderhoud PW P PR PNR PNRZ 6 720 817 509 2017 05 71 9 10 11 12 ...
Страница 72: ...9 Onderhoud PW P PR PNR PNRZ 6 720 817 509 2017 05 72 13 14 15 16 6 720 817 501 07 1T 3 2 1 ...
Страница 74: ...9 Onderhoud PW P PR PNR PNRZ 6 720 817 509 2017 05 74 21 22 6 720 806 606 13 1ITL ...
Страница 75: ...9 Onderhoud PW P PR PNR PNRZ 6 720 817 509 2017 05 75 ...
Страница 76: ...Bosch Thermotechnik GmbH Sophienstrasse 30 32 D 35576 Wetzlar www buderus com ...