Operating instructions for Buderus 600 - 11R / 19R / 24R • Edition 08/2003

Boulter Buderus Ltd. • http://www.boulter-boilers.com

Subject to modifications resulting from technical improvements!

5

Electricity supply

This boiler must be earthed.

A mains supply of 230 V - 50Hz is required.

Connection must be made in a way that allows complete 
isolation of the electrical supply such as a double pole 
switch, having a 3 mm 1/8") contact seperation in both 
poles, serving only the boiler and system controls. 
Alternatively, a 3-pin unswitched socket may be used. 
The means of isolation must be accessible to the user 
after installation.

6

Functions of the system and operating 
instructions

The installer should familiarize the user with the 
functions and operation of the heating system and 
ensure that a complete set of technical documentation is 
supplied.

7

Maintenance

The appliance should be serviced at least once a year 
by a CORGI registered installer.

8

Cleaning

For normal cleaning simply dust with a dry cloth.

To remove stubborn marks and stains, wipe with a damp 
cloth and finish off with a dry cloth.

DO NOT use abrasive cleaning materials.

9

Initial start-up

9.1

Operation of the boiler

9.1.1 Access to the control unit

z

Press the window to open the access panel of the 
control unit see fig 1.

Fig. 1

Open the window of control unit

9.1.2 Lighting and shutting down the boiler.

z

Press the mains switch (see fig 2, item 1) on the 
control unit to "

I

" to light the boiler.

z

Press the mains switch to "

0

" to shut down the boiler.

9.1.3 Frost hazard

In the event of any risk of the heating system freezing 
up, you must keep the pump switched on.

Fig. 2

Control panel

9.1.4 Temperature-setting adjustments

z

Set flow temperature at the control unit (fig. 2, item 2) 
(see table 1).

z

Adjust room temperature to maximum setting at the 
control unit.

z

Push the mains power switch (fig. 2, item 1) to “

I

”. 

The boiler runs through the start-up programme and 
the burner is ignited after approx. 30 seconds.

z

Adjust room temperature to desired setting at the 
control unit.

I

NOTE

Knob pos. 3 in fig. 2 is used for service purposes 
only.

*

Basic setting: Have the specific system settings of the Buderus control system and burner-control unit control panel adjusted by 
a specialist heating system company.

Table 1

Flow temperature

I

0

1

10

1

10

2

1

3

Control unit

Range of application

Controller position / boiler flow temperature

230 V temperature 
controller

Floor heating
Radiator heating

1

3

(48 °C, max. factory-adjusted setting for floor heating)

1

7

(67 °C, min. factory-adjusted setting for radiator heating)

ON/OFF temperature 
controller, 24 V

Radiator heating

1

5

(58 °C, new building) up to

10

(80 °C, old building)*