5.3.16 Measuring the ionisation current
See subsection : "Measuring the ionisation current (fig. 35)"
on page 38.
5.3.17 Replacing the ionisation electrode
z
Remove the gas-air unit.
z
Loosen the plug-and-socket connection of the ionization
electrode.
z
Loosen screw (fig. 67, item 1) by a half-turn and slide
bar to remove.
z
Pull electrode to remove, and fit new unit.
z
Reassemble by following the above procedure in
reverse.
5.3.18 Checking KIM connections
z
Locate KIM on the side of the UBA bracket.
z
Check if 4 pin connector (fig. 68, item 1) is fitted and
secure.
Fig. 67 Replacing the ionisation electrode
1
Fig. 68 KIM connections
1
NOTE
This is not a servicable part and any fault
identified with this component, contact
Buderus.