Page 7
GAS CONNECTION
Check gas type. Use only the type of gas indicated on the valve rating plate. If the type of gas
listed on the plate is not your type of gas supply, DO NOT INSTALL. Contact your dealer for
proper model.
Always use an external regulator for all LP heaters to reduce the supply tank pressure to a
maximum of 13" W.C. This is in addition to the regulator furnished with the heater.
Warning:
Connection directly to an unregulated LP tank can cause an explosion.
The normal gas connection is 3/8" N.P.T. made at the right side facing the log set. If a left side
connection is desired, the connecting pipe may be routed under the back of the burner base to
terminate at the right hand side for connection to the inlet of the valve.
NOTE: The connecting pipe must be internally tinned copper tubing for use with natural gas.
Test for leaks using a solution of soap and water after completing the connection. DO NOT
USE OPEN FLAME.
PREPARING LOG KIT
Open the cartons containing the Burner Base and the logs. Inside one of the cartons you will
find the Burner Base. The logs are boxed separately.
WARNING:
POSITIONING OF LOGS IS VERY CRITICAL (See Figure 2).
LOG PLACEMENT FOR 18 (FIBER) LOG SETS:
1) Place back log (flat faced)#1 on back log support. The log has alignment notches on each
corner.
2) Place ember strip (wrapped in cardboard box)#2 on front bottom andirons. Center from
side to side.
3) Next place middle log (with ember burn out)#3 over front burner tube. The two ends are
notched out on bottom to ensure proper fitting over ends of burner.
4)
Right top log is a “y”
shaped log #4. The round stem lays in the notched out space on the
right top corner of back log. There is a pin on the middle log, and a hole on the flattened
end of the top left log. Place hole over pin.
5) Place one end of the left top log #5 in notch of left corner on back log and the other end of
the left top log in notch on top middle log.
Solid fuels shall not be burned in the same fireplace where an unvented room heater has been
installed.
NOTE: The following label has been provided with this appliance and must be read and then
attached to the floor of the fireplace or firebox area beneath the appliance. The label is a peel
and stick label. Make sure the area is cleaned before attaching the label to it.
WARNING:
This solid-fuel burning fireplace or listed ventless enclosure has been
converted for use with an unvented fireplace insert only. A solid-fuel burning fireplace
cannot be used for burning wood or solid fuels unless all original parts have been
replaced, and the fireplace re-approved by the authority having jurisdiction. A ventless
firebox enclosure cannot be used with an unvented gas log unless all original parts have
been replaced, and the ventless firebox enclosure re-approved by the authority having
jurisdiction.