Buckleys DRY ROOF PRO2 Скачать руководство пользователя страница 9

 

9

 

Setup (continued) 

 

 

 

 

 

 

 

 

Instrument settings 

Switch the instrument on by pressing 

a

. The screen displays 

the following information (see fig.8): 

A

  Battery level indicator 

B

  Test probe handle connected 

C

  Voltage currently applied to electrode 

D

  Current draw at electrode 

E

  Output lock ON/OFF 

F

  Sensitivity threshold 

G

  Set test voltage 

H

  Sensitivity threshold graph 

Handle temperature 

Setting interface language 

Press 

b

 to access the main settings menu and press 

d

 or 

e

 to scroll to 

Set Language

 and press 

b

. Press 

d

 or 

e

 to 

scroll to the desired language and press 

b

. Press 

c

 to 

return to the main display screen. 

Setting the output voltage 

Press 

b

 to access the main settings menu and press 

d

 or 

e

 to scroll to 

Adjust Voltage

 and press 

b

. Press 

d

 or 

e

 until 

the display shows the desired voltage and press 

b

. Press 

c

 

to return to the main display screen. 

Setting the sensitivity threshold 

Press 

b

 to access the main settings menu and press 

d

 or 

e

 to scroll to 

Adjust Sensitivity

 and press 

b

. Press 

d

 or 

e

 

until the display shows the desired number and press 

b

Press 

c

 to return to the main display screen.  

Setting the Alarm Suppression 

Press 

b

 to access the main settings menu and press 

d

 or 

e

 to scroll to 

Alarm Suppression

 and press 

b

. Press 

d

 or 

e

 

until the display shows the desired number and press 

b

Press 

c

 to return to the main display screen. 

Refer to page 5 for more information on sensitivity settings. 

Setting test thickness via a standard 

Press 

b

 to access the main settings menu and press 

d

 or 

e

 to scroll to 

Test Standard

 and press 

b

. Press 

d

 or 

e

 to 

scroll to the desired test standard and press 

b

. Press 

c

 to 

return to the main display screen. 

Press 

d

 or 

e

 to input the thickness of the test material. The 

calculated test voltage is displayed below the set test 

thickness. 
When all settings are correct, test the instrument by holding 

down the ON button on the test probe handle and briefly 

placing the electrode in contact with a suitable 

conductive, grounded item. The alarm system should 

trigger (See Fig.9). 

The user should establish, in conjunction with their 

client, and having regard for the material being 

tested, appropriate test conditions to be applied. In 

the absence of a customer specification, Buckleys 

has found NACE SP0274 to be a useful general-

purpose standard, however, it remains the user’s 

responsibility to establish safe and reliable testing 

conditions.  We would recommend an initial sensitivity 

setting of 350uA and a suppression setting of 4, but 

these should be checked, ideally on a test area of 

the same membrane material, and optimised as 

advised on page 5. 

Содержание DRY ROOF PRO2

Страница 1: ...Electronic Flat Roof Leak Detection and Location Kit Quick Start Guide Please read this guide before using theequipment 5830 0047 11 21 English...

Страница 2: ...nings 3 EC Declaration of Conformity 4 UKCA Declaration of Conformity 4 Specifications 4 Maintenance 5 Register Your Product 5 Useful Advice 5 Kit Contents 6 Risk Assessment 7 Factory Settings 7 Setup...

Страница 3: ...eing immersed in water It must be immediately returned to Buckleys for service calibration and or repair A high voltage will always take the easiest route to earth The risk of electrical shock is inhe...

Страница 4: ...nge without notice or obligation Output voltage range 0 9kV 40kV Max output current 1mA continuous Alarm sensitivity range 10 A to 450 A factory set to 200 A Recommended coating thickness range 13 m 2...

Страница 5: ...mmediately To register your product simply visit www buckleysinternational com registration complete the online form and click on SUBMIT Useful Advice Instrument sensitivity Several variables includin...

Страница 6: ...5m earth cable on reel H D cell rechargeable batteries x4 I Battery charger with mains power adaptors and in car charger J Mid section extension rod x2 K End section extension rod L 450mm angled phosp...

Страница 7: ...materials been removed from the area to be tested EMC RFI Buckleys high voltage instruments will produce sparks which may create interference in nearby electronic apparatus particularly communication...

Страница 8: ...Quick Start Guide 8 Setup...

Страница 9: ...croll to Alarm Suppression and press b Press d or e until the display shows the desired number and press b Press c to return to the main display screen Refer to page 5 for more information on sensitiv...

Страница 10: ...Quick Start Guide 10 Basic Testing Press and hold the ON button 1m sec...

Страница 11: ...11 Basic Testing continued...

Страница 12: ...ish Contact Details Manufacturer Buckleys UVRAL Ltd Address Buckleys House Unit G Concept Court Shearway Business Park Shearway Road Folkestone Kent CT19 4RG UK Tel 44 0 1303 278888 Email sales buckle...

Отзывы: