Maintenance 

The Dry Roof Pro2 is designed for minimum maintenance by the user, however the following periodic 
checks/actions are recommended: 

The exterior of the unit should be cleaned 
regularly. Stubborn dirt may be removed with a 
moistened cloth (99% water +1% mild 
detergent). Mild solutions may be used to 
remove greasy dirt. Do not allow cleaning fluid 
to enter the unit. The use of other cleaning 
agents may lead to damage to the detector’s 
surface areas.

Our service team will ensure your detector’s 
performance is within our strict tolerances and 
carry out a thorough inspection of the entire kit; 
advising you of any repairs required. 

It is advisable to remove the batteries and keep 
them fully charged when the unit is not in use.

 

NOTE: 

The Dry Roof Pro2 requires annual calibration by an approved provider. For more 

details, visit: 

www.buckleysinternational.com/repairs

Register Your Product 

Please register this product via Buckleys’ 
website and download the Warranty 
Registration Certificate. 
Once your product is registered, you will receive 
the following benefits: 

 

Annual service & calibration reminders by 

email 

 

Latest industry news relating to your product 

 

Be the first to hear about our new products 

We strive to improve the quality of our products 
and service. By registering your product, you 
can help us monitor overall quality of our 
products, service and dealer network. 
Additionally, if we ever need to contact you 
regarding your product, we are able to do so 
immediately. 
To register your product, simply visit: 

www.buckleysinternational.com/registration 

... complete the online form and click on ‘

SUBMIT

Useful Advice 

Instrument sensitivity

Several variables including the test material 
itself, temperature, solar load and electrode 
type and size will impact the sensitivity setting 
required. The detector will show a low-level 
current draw in micro-amps (µA) as the 
electrode is passed over a coating. A sensitivity 
setting around 100µA above the displayed 
current draw is often suitable; although 
attention should be given to verify the 
effectiveness of the sensitivity setting; too low 
may cause false-alarms and too high could 
cause faults to go undetected. 
It may not always be possible to determine a 
suitable sensitivity setting. In such cases, 
increasing the sensitivity until the detector 
switches to ‘Spark Only’ mode prevents the 
alarm from triggering unless a direct connection 
to ground is made. A higher test voltage may 

be required to compensate for current drawn 
as the electrode passes over the coating. This 
method is less precise and will not detect weak 
or thin areas as readily. 
This new generation instrument is capable of 
detecting flaws much more rapidly than 
previous models.  As a result of this, it is possible 
to get multiple alerts for a single flaw, which 
may be inconvenient or distracting for the 
operator.  In this case, the Alarm Suppression 
may be adjusted – a setting of zero indicates no 
suppression, and higher settings will 
progressively reduce the likelihood of multiple 
alerts.   
We recommend using the lowest comfortable 
setting as this reduces the chances of missing a 
second flaw close to one detected first.

 

 

Содержание DRY ROOF PRO2

Страница 1: ...Electronic Flat Roof Leak Detection and Location Kit Quick Start Guide Please read this guide before using theequipment 5830 0047 11 21 English...

Страница 2: ...nings 3 EC Declaration of Conformity 4 UKCA Declaration of Conformity 4 Specifications 4 Maintenance 5 Register Your Product 5 Useful Advice 5 Kit Contents 6 Risk Assessment 7 Factory Settings 7 Setup...

Страница 3: ...eing immersed in water It must be immediately returned to Buckleys for service calibration and or repair A high voltage will always take the easiest route to earth The risk of electrical shock is inhe...

Страница 4: ...nge without notice or obligation Output voltage range 0 9kV 40kV Max output current 1mA continuous Alarm sensitivity range 10 A to 450 A factory set to 200 A Recommended coating thickness range 13 m 2...

Страница 5: ...mmediately To register your product simply visit www buckleysinternational com registration complete the online form and click on SUBMIT Useful Advice Instrument sensitivity Several variables includin...

Страница 6: ...5m earth cable on reel H D cell rechargeable batteries x4 I Battery charger with mains power adaptors and in car charger J Mid section extension rod x2 K End section extension rod L 450mm angled phosp...

Страница 7: ...materials been removed from the area to be tested EMC RFI Buckleys high voltage instruments will produce sparks which may create interference in nearby electronic apparatus particularly communication...

Страница 8: ...Quick Start Guide 8 Setup...

Страница 9: ...croll to Alarm Suppression and press b Press d or e until the display shows the desired number and press b Press c to return to the main display screen Refer to page 5 for more information on sensitiv...

Страница 10: ...Quick Start Guide 10 Basic Testing Press and hold the ON button 1m sec...

Страница 11: ...11 Basic Testing continued...

Страница 12: ...ish Contact Details Manufacturer Buckleys UVRAL Ltd Address Buckleys House Unit G Concept Court Shearway Business Park Shearway Road Folkestone Kent CT19 4RG UK Tel 44 0 1303 278888 Email sales buckle...

Отзывы: