5.0 Maintenance
5.1 Periodic maintenace
Before any kind of service or adjustment, remove the battery from the power unit.
Preventive maintenance should be performed according to the recommended intervals. This is
important for maintaining a well-functioning function and quality, without unnecessary stops
and interruptions.
Description
Interval
Measure
Die and die holder
Daily
Inspect and clean if
necessary (dirt, chips,
deposits, galvanized
residues).
Punch
Daily
Check the punch
Stripper spring
Every week
Make sure the stripper
spring is free from cracks
and deposits.
After abt 20 000 cycles or
when changing punch
Change stripper spring
Battery
Daily or when the indicatior
light flashes.
Change the battery to a full
charge. Put the replaced
battery in the charger.
Spare parts
In need of spare parts, please contact
BTM Scandinavia AB
Franska vägen 32
S-392 56 KALMAR
Tel. +46 480 868 75