B T L - 5 0 0 0 S E R I E S
U S E R ' S M A N U A L
p a g e 5 0 o f 5 6
8 U N I T S
C O N F I G U R A T I O N S
8 . 1 T A B L E O F C O N F I G U R A T I O N S O F T H E C O M B I N E D D E V I C E S B T L
5 0 0 0 C O M B I
Type: 5800SL
5810S
5810S2 5810SL
5810L
5810L2
5820S
5825S
Number
of
therapies
2 2 3 3 2 3 3 3
Electrotherapy
1 1 1 1 1 2 2
Ultrasound
therapy
1 1 2 1 1 1
Laser
therapy
1 1 1 2
Patient cardfile (positions)
min. 150
min. 150
min. 150
min. 150
min. 150
min. 150
min. 150
min. 150
User programs
min. 150
min. 150
min. 150
min. 150
min. 150
min. 150
min. 150
min. 150
User sequences
min. 50
min. 50
min. 50
min. 50
min. 50
min. 50
min. 50
min. 50
Step of setting of values
standard
standard
standard standard standard standard standard standard
Encyclopaedia
x x x x x x x x
Preset
diagnoses
Preset
programs
Preset
sequences
Programs
Interconnection with PC
optional
optional
optional optional optional optional optional optional
optional optional optional optional optional optional optional optional
Language
versions
x x x x x x x x
Sound
schemes
x x x x x x x x
Display, diagonal
b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
b/w
14.6 cm
Screen
saver
x x x x x x x x
Colour
schemes
Recent
performed
therapies
20 20 20 20 20 20 20 20
Electro parameters:
Channel mode
CC / CV
CC / CV
CC / CV
CC / CV
CC / CV
CC / CV
CC / CV
Galvanic,
Iontophoresis
x x x x x x x
Träbert,
Farad,
Neofarad x x x x x x x
Diadynamics
x x x x x x x
TENS
x x x x x x x
Rectangular
pulses
x x x x x x x
Triangular
pulses
x x x x x x x
Exponential
pulses
x x x x x x x
Combined
pulses
x x x x x x x
Interrupted
pulses
x
Pulse modulation:
x x x x x x x
random
frequency
sweep
x x x x x x x
burst,
surges
x x x x x x x
Stimulation
pulses
x x x x x x x
Russian
stimulation
x x x x x x x
2-pole
interference
x x x x x x x
4-pole
interference
x x
Isoplanar
field
(interference)
x
Vector
field
(interference) x
Electrodiagnostics:
x
I/t
curve
(memory
position)
min.
50
HVT
optional
optional optional optional
optional
H
–
waves
x
Spastic
currents
Microcurrents
x
Leduc's
current
x
Mid-frequency
surges
Ultrasound parameters:
Head of 4 cm
2
, 1 and 3 MHz
x
x
x
x
x
x
Head of 1 cm
2
, 1 and 3 MHz
optional
optional
optional
optional
optional
optional
Detection of contact
continuous continuous continuous continuous
continuous
continuous
Continuous
operation
mode
x x x x x x
Pulse operation mode
x
x
x
x
x
x
Duty
factor
x x x x x x
Laser parameters:
Max. laser output, 685 nm
50 mW
50 mW
50 mW
50 mW
Max. laser output, 830 nm
400 mW
400 mW
400 mW
400 mW
Continuous
operation
mode
x x x x
Pulse operation mode
x
x
x
x
Duty
factor
x x x x
Nogier
frequencies
x x x x
EAV
frequencies
x x x x
Devices of types 5815 and 5821 have similar properties as 5810, but have some additional types of currents.