The following functions correspond to the configurator in position M:
Scenario command
Scenario number
scenario module
Configurator
M = 5
Configurator
M
=
6
Configurator
M
=
7
Configurator
M
=
8
Scenario 1
Key 1
Scenario 2
Key 2
Scenario 3
Key 3
Scenario 4
Key 4
Scenario 5
Key 1
Scenario 6
Key 2
Scenario 7
Key 3
Scenario 8
Key 4
Scenario 9
Key 1
Scenario 10
Key 2
Scenario 11
Key 3
Scenario 12
Key 4
Scenario 13
Key 1
Scenario 14
Key 2
Scenario 15
Key 3
Scenario 16
Key 4
Description
Configurator in M
Spacer mounted
on the key covers
Cyclical ON/OFF command (adjusts intensity for long press)
No configurator
YES
ON command
ON
YES
OFF command
OFF
YES
ON command pressing the upper key, OFF pressing the lower key
(adjusts intensity for long press)
O/I
NO
Rolling shutters UP/DOWN to limit switch command
⇑⇓
NO
Rolling shutters UP/DOWN for the time the key is pressed command
⇑⇓
M
NO
Pushbutton mode
PUL
YES
Mixed modes
KEY A: Cyclical
KEY B: Up/Down
1
KEY COVER A: YES
KEY COVER B: NO
KEY A: Cyclical
KEY B: Up/Down Monostable
2
KEY COVER A: YES
KEY COVER B: NO
KEY A: O/I
KEY B: Up/Down
3
NO
KEY A: O/I
KEY B: Up/Down Monostable
4
NO
Scenario command
(1)
5÷8
NO
(1) Scenario command
This mode is only used if the system has scenario module item F420. It can call (not program) a scenario already saved in the
scenario module.
In this mode of operation A PL1 represents the address of the scenario module to be commanded. The command calls a scenario
between 1 and 16 depending on the configurator in M and on the pushbutton which is pressed as indicated in the table below.
Power supply: CR2032 3V battery
Operating temperature: +5°C ÷ +35°C
Minimum battery lifetime: 2 years
Radio frequency: 868 MHz
Range: 100m in free space (metal and cement walls or metal plates reduce the range)
Type of modulation: FSK
TECHNICAL DATA
DECLARATION OF CONFORMITY
Items
HC/HS4572
and
H4572PI
conform to the essential requirements of directive 1999/5/CE, because they respect the following standards:
ETSI EN301 489-3 ETSI EN300 220-3
Year of approval of the CE marking according to the directive indicated: 2005