7
31/07/2018
ST-00000361-
344642 - 344643
EN
Systems made with traditional internal units only.
MAXIMUM LINE A DISTANCE, ENTRANCE PANEL - FURTHEST HANDSET
Cable section mm
2
2 normal c
ables
> 0.2 mm
2
BT
icino c
able
336904
0,5 mm
2
Telephone t
wist
ed
pair 0.28 mm
2
A pair of the multi-
pair da
ta c
able C
AT5
2 IU/2 pushbuttons
50 m
200 m
140 m
180 m
5 IU/5 pushbuttons
50 m
200 m
140 m
155 m
10 IU/10 pushbuttons
50 m
200 m
140 m
145 m
26 IU/26 pushbuttons
50 m
200 m
140 m
125 m
38 IU/38 pushbuttons
50 m
200 m
140 m
110 m
38 IU/38 pushbuttons with local
power supply
50 m
200 m
140 m
170 m
38 IU/digital call modules
50 m
200 m
140 m
115 m
64 IU/digital call modules
50 m
200 m
140 m
-
MAXIMUM LINE C DISTANCE, POWER SUPPLY - FURTHEST HANDSET
Cable section mm
2
2 normal c
ables
> 0.2 mm
2
BT
icino c
able
336904
0,5 mm
2
Telephone t
wist
ed
pair 0.28 mm2
A pair of the multi-
pair da
ta c
able C
AT5
2 IU in/out
50 m
200 m
130 m*
90 m*
5 IU in/out
50 m
200 m
130 m
90 m
10 IU in/out
50 m
190 m
120 m
80 m
26 IU in/out
50 m
170 m
110 m
70 m
5 HA (shunted)
50 m
200 m
110 m
80 m
10 HA (shunted)
50 m
160 m
100 m
70 m
26 HA (shunted)
50 m
130 m
80 m
60 m
38 HA (shunted)
50 m
110 m
70 m
50 m
64 HA (shunted)
+
85 m
55 m
-
MAXIMUM LINE D DISTANCE ENTRANCE PANEL - DOOR LOCK
Cable section mm
2
0.28 mm
2
BT
icino c
a-
ble L4669
0,35 mm
2
BT
icino
cable
336904
0,5 mm
2
1 mm
2
S+ S- clamps
30 m
30 m
50 m
100 m
If all the “advanced” internal units in the system are supplied locally the system should be considered as being made with “traditional” internal units only.
Risers with max 26 IU should be made in systems with more than 26 internal units.
Systems made with at least one advanced internal unit.
MAXIMUM LINE A DISTANCE, ENTRANCE PANEL - FURTHEST HANDSET
Cable section mm
2
2 normal c
ables
> 0.2 mm
2
BT
icino c
able
336904
0,5 mm
2
Telephone t
wist
ed
pair 0.28 mm
2
A pair of the multi-
pair da
ta c
able C
AT5
2 IU/2 pushbuttons
50 m
200 m
140 m
145 m
5 IU/5 pushbuttons
50 m
200 m
140 m
135 m
10 IU/10 pushbuttons
50 m
200 m
140 m
130 m
26 IU/26 pushbuttons
50 m
200 m
140 m
105 m
38 IU/38 pushbuttons
50 m
200 m
140 m
95 m
38 IU/38 pushbuttons with local
power supply
50 m
200 m
140 m
155 m
38 IU/digital call modules
50 m
200 m
140 m
90 m
MAXIMUM LINE C DISTANCE, POWER SUPPLY - FURTHEST HANDSET
Cable section mm
2
2 normal c
ables
> 0.2 mm
2
BT
icino c
able
336904
0,5 mm
2
Telephone t
wist
ed
pair 0.28 mm
2
A pair of the multi-
pair da
ta c
able C
AT5
2 IU in/out
50 m
150 m
100 m
65 m
5 IU in/out
50 m
140 m
90 m
60 m
10 IU in/out
50 m
130 m
80 m
60 m
26 IU in/out
50 m
110 m
70 m
50 m
5 HA (shunted)
50 m
140 m
90 m
60 m
10 HA (shunted)
50 m
120 m
80 m
55 m
26 HA (shunted)
50 m
95 m
60 m
40 m
38 HA (shunted)
50 m
80 m
50 m
35 m
MAXIMUM LINE B DISTANCE, ENTRANCE PANEL - POWER SUPPLY
Cable section mm
2
2 normal c
ables
> 0.2 mm
2
o
L4669
BT
icino c
able
336904
0,5 mm
2
telephone t
wist
ed
pair 0.28 mm
2
a pair of the multi-
pair da
ta c
able C
AT5
2 pushbuttons
50 m
200 m
115 m
90 m
10 pushbuttons
50 m
170 m
100 m
75 m
26 pushbuttons
50 m
150 m
95 m
65 m
38 pushbuttons
50 m
140 m
90 m
60 m
≥ 38 pushbuttons with local
power supply
50 m
200 m
140 m
120 m
digital call
50 m
150 m
95 m
65 m
MAXIMUM LINE D DISTANCE ENTRANCE PANEL - DOOR LOCK
Cable section mm
2
0.28 mm
2
BT
icino
cableL4669
0,35 mm
2
BT
icino c
a-
ble 336904
0,5 mm
2
1 mm
2
S+ S- clamps
30 m
30 m
50 m
100 m
MAXIMUM LINE B DISTANCE, ENTRANCE PANEL - POWER SUPPLY
Cable section mm
2
2 normal c
ables
> 0.2 mm
2
o
L4669
BT
icino c
able
336904
0,5 mm
2
telephone t
wist
ed
pair 0.28 mm
2
a pair of the multi-
pair da
ta c
able C
AT5
2 pushbuttons
50 m
200 m
115 m
90 m
10 pushbuttons
50 m
170 m
100 m
75 m
26 pushbuttons
50 m
150 m
95 m
65 m
38 pushbuttons
50 m
140 m
90 m
60 m
≥ 38 pushbuttons with local
power supply
50 m
200 m
140 m
120 m
digital call
50 m
150 m
95 m
65 m
Maximum distances and cable features
CLASSE 300X13E
Touch Screen handsfree video internal units
with Wi-Fi