background image

4

31/07/2018

ST-00000361-

J1 J2

N

P

M

J1 J2

N

P

M

344642 - 344643

EN

The possible configurations are shown in the table of the following page.

LEGEND

P

+1

MOD=9

P+1

P

+2

MOD=9

P+2

P

P+1

MOD=5

P+1 P+1

2

3

1

3

2

346210

1

P+2

MOD=5

P+2 P+2

2

3

1

3

2

346210

1

P+3

MOD=5

P+3 P+3

2

3

1

3

2

346210

1

P+4

MOD=5

P+4 P+4

2

3

1

3

2

346210

1

1

–+

23

4

P

+3

MOD=9

P+3

1

–+

23

4

2

3

1

3

2

346210

1

1 Activation of the EP (configured with P+1) directly 
without call or activation of the actuator item 
346200/346210 (configured with P+1 and MOD=9).

P

+1

MOD=9

P+1

P

+2

MOD=9

P+2

P

P+1

MOD=5

P+1 P+1

2

3

1

3

2

346210

1

P+2

MOD=5

P+2 P+2

2

3

1

3

2

346210

1

P+3

MOD=5

P+3 P+3

2

3

1

3

2

346210

1

P+4

MOD=5

P+4 P+4

2

3

1

3

2

346210

1

1

–+

23

4

1

–+

23

4

P

+3

MOD=9

P+3

1

–+

23

4

EP door lock release (configured with P+1), directly 
without call, or activation of the actuator item 
346200/346210 (configured with P+1 and MOD=5), 
or activation of door lock actuators item 346230 
(configured with P+1).

P

+1

MOD=9

P+1

P

+2

MOD=9

P+2

P

P+1

MOD=5

P+1 P+1

2

3

1

3

2

346210

1

P+2

MOD=5

P+2 P+2

2

3

1

3

2

346210

1

P+3

MOD=5

P+3 P+3

2

3

1

3

2

346210

1

P+4

MOD=5

P+4 P+4

2

3

1

3

2

346210

1

1

–+

23

4

1

–+

23

4

P

+3

MOD=9

P+3

1

–+

23

4

EP door lock release (configured with P+2), directly 
without call, or activation of the actuator item 
346200/346210 (configured with P+2 and MOD=5), 
or activation of door lock actuators item 346230 
(configured with P+2).

P

+1

MOD=9

P+1

P

+2

MOD=9

P+2

P

P+1

MOD=5

P+1 P+1

2

3

1

3

2

346210

1

P+2

MOD=5

P+2 P+2

2

3

1

3

2

346210

1

P+3

MOD=5

P+3 P+3

2

3

1

3

2

346210

1

P+4

MOD=5

P+4 P+4

2

3

1

3

2

346210

1

1

–+

23

4

1

–+

23

4

P

+3

MOD=9

P+3

1

–+

23

4

EP door lock release (configured with P+3), directly 
without call, or activation of the actuator item 
346200/346210 (configured with P+3 and MOD=5), 
or activation of door lock actuators item 346230 
(configured with P+3).

P

+1

MOD=9

P+1

P

+2

MOD=9

P+2

P

P+1

MOD=5

P+1 P+1

2

3

1

3

2

346210

1

P+2

MOD=5

P+2 P+2

2

3

1

3

2

346210

1

P+3

MOD=5

P+3 P+3

2

3

1

3

2

346210

1

P+4

MOD=5

P+4 P+4

2

3

1

3

2

346210

1

1

–+

23

4

1

–+

23

4

P

+3

MOD=9

P+3

1

–+

23

4

EP door lock release (configured with P+4), directly 
without call, or activation of the actuator item 
346200/346210 (configured with P+4 and MOD=5), 
or activation of door lock actuators item 346230 
(configured with P+4).

Intercom among apartments in systems with apartment 
interface item 346850.

Intercom inside the apartment, in systems with apartment 
interface item 346850, or intercom among apartments in 
systems without apartment interface.

Internal intercom. It sends the call to all the handsets with 
the same address.

Paging, it makes general intercom and sends a call to all 
the handsets of the system.

The functions that can be attributed to the Favorite key ( ) using the physical 
procedure, using the configurator inserted in the MM-(

units

) socket are the following:

The MM - (tenths) physical configurator decides which are the 4 QUICK ACTIONS icons 
that appear on the HOME PAGE, and can be activated by touching the display.

MM =

0

Staircase Light Control

MM =

1

Direct control of (P+1) door lock

P

+1

MOD=9

P+1

P

+2

MOD=9

P+2

P+1

MOD=5

P+1 P+1

2

3

1

3

2

346210

1

P+2

MOD=5

P+2 P+2

2

3

1

3

2

346210

1

P+3

MOD=5

P+3 P+3

2

3

1

3

2

346210

1

P

+3

MOD=9

P+3

MM =

2

Direct control of (P+2) door lock.

P

+1

MOD=9

P+1

P

+2

MOD=9

P+2

P+1

MOD=5

P+1 P+1

2

3

1

3

2

346210

1

P+2

MOD=5

P+2 P+2

2

3

1

3

2

346210

1

P+3

MOD=5

P+3 P+3

2

3

1

3

2

346210

1

P

+3

MOD=9

P+3

 

MM =

3

Direct control of (P+3) door lock.

P

+1

MOD=9

P+1

P

+2

MOD=9

P+2

P+1

MOD=5

P+1 P+1

2

3

1

3

2

346210

1

P+2

MOD=5

P+2 P+2

2

3

1

3

2

346210

1

P+3

MOD=5

P+3 P+3

2

3

1

3

2

346210

1

P

+3

MOD=9

P+3

MM =

4

(P+1) direct auto-switching on.

P

+1

MOD=9

P+1

P

2

3

1

3

2

346210

1

P

+2

MOD=9

P+2

2

3

1

3

2

346210

1

P

+3

MOD=9

P+3

2

3

1

3

2

346210

1

MM =

5

(P+2) direct auto-switching on.

P

+1

MOD=9

P+1

P

2

3

1

3

2

346210

1

P

+2

MOD=9

P+2

2

3

1

3

2

346210

1

P

+3

MOD=9

P+3

2

3

1

3

2

346210

1

 

MM =

6

(P+3) direct auto-switching on.

P

+1

MOD=9

P+1

P

2

3

1

3

2

346210

1

P

+2

MOD=9

P+2

2

3

1

3

2

346210

1

P

+3

MOD=9

P+3

2

3

1

3

2

346210

1

MM =

7

Paging.

MM =

8

Internal intercom.

MM =

9

Enabling/disabling Professional Studio 
function.

CLASSE 300X13E

Touch Screen handsfree video internal units 

with Wi-Fi

Содержание CLASSE 300X13E

Страница 1: ...n 400 mA Additional power supply of clamp 1 2 27Vdc Maximum absorption from clamp 1 2 250 mA Operating temperature 5 40 C The Classe 300X video internal unit must be connected to a Wi Fi network with...

Страница 2: ...Installer Manual how to enable the functions The background and icons shown may differ from those on the device Front view Rear view Note When the DOOR ENTRY is connected to the system e g answer a c...

Страница 3: ...s of the device identify the associated EP which is the first entrance panel that switches itself on when the pushbutton is pressed the first time as well as which door lock is activated when pressing...

Страница 4: ...D 5 P 4 P 4 2 3 1 3 2 346210 1 1 23 4 1 23 4 P 3 MOD 9 P 3 1 23 4 EP door lock release configured with P 4 directly without call or activation of the actuator item 346200 346210 configured with P 4 an...

Страница 5: ...2 N 1 N 3 N 3 N 1 N 2 P 1 MOD 5 P 1 P 1 2 3 1 3 2 346210 1 P 2 MOD 5 P 2 P 2 2 3 1 3 2 346210 1 MM 6 MM 7 MM 8 MM 9 N 2 N 3 N 4 N 5 N 1 N 1 N 4 N 3 N 5 N 2 N 1 N 4 N 2 N 5 N 3 N 1 N 3 N 2 N 5 N 4 N 1...

Страница 6: ...hes and if closed the LED stays off WARNING the function can only be activated if required by the system accessory devices are required CANNOT BE ACTIVATED together with the PROFESSIONAL STUDIO OFFICE...

Страница 7: ...he multi pair data cable CAT5 2 IU 2 pushbuttons 50 m 200 m 140 m 145 m 5 IU 5 pushbuttons 50 m 200 m 140 m 135 m 10 IU 10 pushbuttons 50 m 200 m 140 m 130 m 26 IU 26 pushbuttons 50 m 200 m 140 m 105...

Страница 8: ...0 344642 344643 346020 344642 344643 346020 344642 344643 344642 344643 EN Wiring diagrams Below are some examples of connection of the CLASSE 300X13E 344642 344643 video handset in multi family 2 wir...

Страница 9: ...344612 344613 344612 344613 344642 344643 344612 344613 344612 344613 346020 346020 31 07 2018 ST 00000361 344642 344643 EN Wiring diagrams DIAGRAM 2 EXAMPLE OF MULTI FAMILY SYSTEM WITH ADDITIONAL INT...

Страница 10: ...346000 346850 F441 344642 344643 344612 344613 344612 344613 344612 344613 344612 344613 346000 346850 F441 344642 344643 344612 344613 344612 344613 344612 344613 344612 344613 346000 346850 F441 31...

Страница 11: ...4612 344613 346000 344612 344613 344612 344613 344612 344613 346830 343081 343091 344642 344643 EN Wiring diagrams DIAGRAM 5 EXAMPLE OF TWO FAMILY DIAGRAM DIAGRAM 4 EXAMPLE OF SINGLE FAMILY DIAGRAM VI...

Отзывы: