background image

Functions

<Tracheostomy care / Endotracheal suction>

Practicing tracheostomy care is possible. 
Please do the training after injecting artificial saliva of 20~30cc with a injector for endotracheal suction.

When practicing gastrostomy tube care or PEG care, remove the chest skin and rib part of manikin, 
insert a gastrostomy tube by opening the cap of stomach, seal the skin and procee the training.

<Gastrostomy tube / PEG care>

Содержание BT-CSIS

Страница 1: ...Tube Feeding Training Model USER S GUIDE BT CSIS ...

Страница 2: ......

Страница 3: ...cts E mail 310 x 700 x 238 9 Tube Feeding Training Model BT CSIS BT Inc South Korea www btinc co kr Headquarter A 313 Samsong Techno valley 140 Tongil ro Deogyang gu Goyang si Gyeonggi do 10594 South Korea Sales Busan Building 5F 27 Jeonpo daero 92beon gil Nam gu Busan 48404 South Korea Headquarter 82 2 2038 2903 Sales 82 51 903 1144 bt btinc co kr ...

Страница 4: ...ty Also making imitated or altered products for commercial purposes are prohibited by law Keep the product away from water and moisture Do not keep the product near hot or cold environments as possible Deterioration of product or internal damage may occur by the extreme weather conditions Never clean the product with chemicals such as solvent benzene or thinner as these may cause fire ignition or ...

Страница 5: ...bag User manual Pedestal for semi sitting position Fixing bolts for Semi setting position Injector connector for endotracheal suction Draining connector Water inlet Funnel Draining tube Injector for endotracheal suction 5 0 6 0 4 0 3 0 2 0 1 0 ...

Страница 6: ...10 Put the manikin in a supine position lock the valve of the draining tube and insert it into the draining connector of manikin Insert the injector for endotracheal suction to the connector and open the valve of water inlet on the abdomen Open the water inlet valve insert the funnel and fill it with 300cc 350cc of water 50 60 40 30 20 10 ...

Страница 7: ...tion How to change the Semi sitting position Supine position Sitting position Semi sitting position 21 45 45 42 39 36 33 30 27 24 21 Loosen and remove bolts at the top adjust the pedestal to the angle 45 42 39 36 33 30 27 24 21 ...

Страница 8: ...ining tube 45 42 39 36 33 30 27 24 21 When practicing tube feeding set the manikin to sitting or semi sitting position and practice according to the way of inserting the catheter When injecting nutrition after inserting a catheter inject nutrition after open the valve of darining tube ...

Страница 9: ...aining after injecting artificial saliva of 20 30cc with a injector for endotracheal suction When practicing gastrostomy tube care or PEG care remove the chest skin and rib part of manikin insert a gastrostomy tube by opening the cap of stomach seal the skin and procee the training Gastrostomy tube PEG care ...

Страница 10: ...l position drain the remaining nutrition fluid and remove the chest skin and rib part of manikin Separate the stomach remove the face skin and then separate the trachea Wash models in running water wipe the surface with a dry cloth and dry it After drying assemble and store in reverse order ...

Страница 11: ...l ro Deogyang gu Goyang si Gyeonggi do 10594 Republic of Korea Hompage www btinc co kr E mail bt btinc co kr Tel 82 2 2038 2903 82 51 903 1144 Fax 82 303 3130 0607 Copyright c BT Inc All rights reserved Tube Feeding Training Model BT CSIS ...

Отзывы: