Example – changing the unit to connect to a Texecom Premier Elite panel via RS485
Inputs
Panel Type
None
Panel Type*
None
Panel Type*
Texecom Premier
Notice –
Saved!
Serial Panel Type
4
2
6
5
7
3
1
Press until shows
Press until shows
Press and hold
Press up arrow for
five seconds to exit
Configuration
Inputs
• Access the configuration menu by holding the Enter button for three seconds.
Press the Enter button again – the display will read ‘Pin Learn’. Press the down arrow
until ‘Serial Panel Type’ is displayed. Press the Enter button again and enter serial
panel type. ‘Default status = None’ will be shown.
• Use the down arrow to scroll through the available panels. Once you reach the
desired panel, hold the Enter button down until ‘Notice – Saved!’ is displayed.
• You’ll then be returned to the same position in the menu to either select another
panel, or use the down arrow to scroll through all the panels to get to the Back option.
• Should you subsequently change from one panel to another, the unit will reboot to
make the panel type change take effect.
You can exit Edit mode at any time, without saving changes, by pressing
for five
seconds. This will return you to the sub-menu that you were making changes in.
Exit the configuration menu at any time without saving any changes by pressing
for
five seconds. This will take you back to the scrolling status display.