BT-62
IR THERMOMETER
OPERATION MANUAL
1. SAFETY RULES
To ensure that the meter is used safely, follow all safety and operating instructions in
this operation manual. If the meter is not used as described in this operation manual,
the safety features of this meter might be impaired.
Do not look directly into the laser beam when the device is in use–permanent eye
damage may result.
Use extreme caution when operating the laser.
Never point the device towards anyone’s eyes.
Keep out of reach of children.
2. INTERNATIONAL SYMBOLS
3. SPECIFICATIONS
Important information
see manual
Laser device. Avoid towards
anyone’s eyes
Measurement Range
-50 to +460°C (-58 to +860°F)
0 to 50°C (32 to 122°F)
0.95 fixed
0.2°C/0.5°F
1sec
Operating Range
Accuracy (Tamb. =
23±3°C)
±1.5°C (2.7°F)
Emissivity
Resolution
Response Time
(90%)
12:1
Distance: Spot
Weight
~180 g (6.3 oz) including batteries (AAA*2pcs)
114 x 162 x 40 mm (4.5 x 6.4 x 1.6 inch)
Battery Life
Typ. 18, min 14 hours continuous use (Alkaline battery)
Dimensions
** The thermometer will automatically shut off if left idle for more than 15sec.
4. THERMOMETER DESCRIPTIONS
5. OPERATION
WARNING
The measurement range is for thermometers only. Users should choose proper probe
types for different kinds of applications. Please make sure the target to be measured
will not exceed the temperature range of the probe to avoid permanent damage to the
thermocouple probe.
Caution: To avoid electric shock and thermometer damage, do not measure the live
circuit with the thermocouple probe voltage exceeding 24V AC RMS or 60V DC.
EMC/RFI: Readings may be affected if the unit is operated within radiofrequency
electromagnetic field strength of approximately 3 volts per meter, but the instrument's
performance will not be permanently affected.
5.1 Function Selection
Display
Function
Simply aim the thermometer at the measure target with Lens (4)
and press Meas. key (6) to display the surface temperature.
During the measurement, the MAX reading will be displayed
beside the icon.
5.2 Other Function Selection
°C of °F
Press Mode Key (2) for °C or °F transferred.
LCD Backlight: Always on.
Recall the last reading memory by pressing Mode Key (2)
while power off
1)
2)
3)
•
•
•
•
•
5.4 LCD Error Messages
The Thermometer incorporates visual diagnostic messages as follows:
‘Er2’ is displayed when the thermometer is exposed to rapid
changes in the ambient temperature. ‘Er3’ is displayed
when the ambient temperature exceeds 0°C(32°F) or +50°C
(122°F).
The thermometer should be allowed plenty of time (minimum
30 minutes) to stabilize to the working/room temperature.
Error 5~9
, for all other error messages it is necessary to reset
the thermometer. To reset it, turn the instrument off, remove the
battery and wait for a minimum of one minute, reinsert the battery
and turn on. If the error message remains please contact the
Service Department for further assistance.
‘Hi’ or ’Lo’ is displayed when the temperature being
measured is outside of the measurement range.
Accuracy (Tobj=
15-35°C,Tamb=25°C)
Tobj=0~460°C: ±2.5% of reading or 2.5°C (4.5°F) whichever is
greater
Tobj=-50~0 °C: ±(2.5°C+0.05/°C)
The thermometer is a non-contact infrared thermometer, and always with Real-Time Maximum
(MAX) data.Please remember to keep away from children and don’t use it for safety related
applications.
Backlight
Laser
Classllla Laser: Always enable while measuring.
Memory
The Distance:Spot is 12:1. Please make sure the target area is
within the field of view.
」
「
」
「
」
「
」
「
」
「