General

General

General

General

General

Maximum network cable length 300m/1000ft

Power consumption <35VA

Mains Voltage 85-270V 50/60Hz

Control ports

Control ports

Control ports

Control ports

Control ports

Logic output voltage 0 or +5V

 unloaded

Logic output impedance 440 Ohm

Opto output series impedance 220 Ohms

 (isolated)

Control input voltage 0 to 4.5v

Control input impedance 4.7kOhms

 to +5V

Opto Output current 14mA

 max

Opto output withstanding voltage (off) 80V

 max.

Network cable wiring

Wiring convention for all CAT.5 cables.

Note:

 Looking at the wiring diagram,

the clip on the terminator is 

facing

away

 (at the back of the connector).

Twisted pairs of wires in the cable are
shown here grouped together.

Содержание Soundweb 9000

Страница 1: ...105 Soundweb TM Soundweb Soundweb Soundweb Soundweb SoundwebTM TM TM TM TM 9000 9000 9000 9000 9000 Installation Guide ...

Страница 2: ...y to remove any protective earth or signal cable shield connections to prevent ground loops Any such disconnections are outside the recommended practice of BSS Audio and will render the EMC or safety certificate void Do not defeat the safety purpose of the polarised grounding plug A polarised plug has 2 blades one wider than the other A grounding type plug has 2 blades and a third grounding prong ...

Страница 3: ...em with the incoming network signal possibly the maximum cable length has been exceeded Activity Activity Activity Activity Activity Flashing This LED indicates data transfer The flashing is not regular but dependant on the rate of transfer The node 1 light also indicates RS232 serial messaging in the same manner DSPClip DSPClip DSPClip DSPClip DSPClip Illuminated Indicates that the signal is clip...

Страница 4: ...ite Orange with 2 Orange 3 White Green with 6 Green 4 Blue with 5 White Blue 7 White Brown with 8 Brown Note There must be at least 1 one 9088 unit in the network with only one node connected For example if you wish to have two 9000 units and one 9088 unit in the same network the 9088 must be a terminal device An example system showing possible connection set ups DCD DSR RX RTS TX GROUND CTS DTR N...

Страница 5: ...stor Two common ground connections are provided connected together internally A LED connected between one output Anode A and common Cathode K will illuminate when the logic output is activated without requiring any external current limiting resistor A high sensitivity relay such as a reed relay may be driven by connecting four outputs in parallel This arrangement will develop 4V across a 500 Ohm c...

Страница 6: ...5V unloaded Logic output impedance 440 Ohm Opto output series impedance 220 Ohms isolated Control input voltage 0 to 4 5v Control input impedance 4 7kOhms to 5V Opto Output current 14mA max Opto output withstanding voltage off 80V max Network cable wiring Wiring convention for all CAT 5 cables Note Looking at the wiring diagram the clip on the terminator is facing away at the back of the connector...

Отзывы: