background image

107

Soundweb

TM

Front panel LED functions

Network monitoring

Network monitoring

Network monitoring

Network monitoring

Network monitoring

Each node has 3 LED indicators showing:

Network

Network

Network

Network

Network

Master

Master

Master

Master

Master

Flashing - 

The network is initialising. If it does not cease to flash, there is a cabling fault -

either a double ring error or a problem with one of the cable connectors.

Steady - 

This node has become the hub master for this unit. It is either directly connected

to the network master, or connected to a ring which contains the network master.

Off - 

This node is slaving to the master's clock.

Sync

Sync

Sync

Sync

Sync

Steady 

- This indicates the presence of a valid network connection on this node.

Flashing - 

There is a problem with the incoming network signal - possibly the maximum

cable length has been exceeded.

Activity

Activity

Activity

Activity

Activity

Flashing 

- This LED indicates data transfer. The flashing is not regular, but dependant on

the rate of transfer.

The node 1 light also indicates RS232 serial messaging in the same manner.

DSP Clip

DSP Clip

DSP Clip

DSP Clip

DSP Clip

Illuminated 

- Indicates that the signal is clipping internally.

Power

Power

Power

Power

Power

Steady 

- This indicates that the power supply is functioning.

RX - 5

GND - 4

TX - 3

RTS - 1

CTS - 2

Front panel details

RS232

RS232

RS232

RS232

RS232

Used to connect one of the 9000 units in the network to a controller PC, which can then
communicate with any device on the network. The pin out is:

Control cable wiring details

All control connections to the 9000 are via Klippon pluggable terminal block connectors
(also known as BL, Phoenix or Combicon). 6-way female Klippon connectors are
supplied for making these connections.

Содержание Soundweb 9000

Страница 1: ...105 Soundweb TM Soundweb Soundweb Soundweb Soundweb SoundwebTM TM TM TM TM 9000 9000 9000 9000 9000 Installation Guide ...

Страница 2: ...y to remove any protective earth or signal cable shield connections to prevent ground loops Any such disconnections are outside the recommended practice of BSS Audio and will render the EMC or safety certificate void Do not defeat the safety purpose of the polarised grounding plug A polarised plug has 2 blades one wider than the other A grounding type plug has 2 blades and a third grounding prong ...

Страница 3: ...em with the incoming network signal possibly the maximum cable length has been exceeded Activity Activity Activity Activity Activity Flashing This LED indicates data transfer The flashing is not regular but dependant on the rate of transfer The node 1 light also indicates RS232 serial messaging in the same manner DSPClip DSPClip DSPClip DSPClip DSPClip Illuminated Indicates that the signal is clip...

Страница 4: ...ite Orange with 2 Orange 3 White Green with 6 Green 4 Blue with 5 White Blue 7 White Brown with 8 Brown Note There must be at least 1 one 9088 unit in the network with only one node connected For example if you wish to have two 9000 units and one 9088 unit in the same network the 9088 must be a terminal device An example system showing possible connection set ups DCD DSR RX RTS TX GROUND CTS DTR N...

Страница 5: ...stor Two common ground connections are provided connected together internally A LED connected between one output Anode A and common Cathode K will illuminate when the logic output is activated without requiring any external current limiting resistor A high sensitivity relay such as a reed relay may be driven by connecting four outputs in parallel This arrangement will develop 4V across a 500 Ohm c...

Страница 6: ...5V unloaded Logic output impedance 440 Ohm Opto output series impedance 220 Ohms isolated Control input voltage 0 to 4 5v Control input impedance 4 7kOhms to 5V Opto Output current 14mA max Opto output withstanding voltage off 80V max Network cable wiring Wiring convention for all CAT 5 cables Note Looking at the wiring diagram the clip on the terminator is facing away at the back of the connector...

Отзывы: