107
Soundweb
TM
Front panel LED functions
Network monitoring
Network monitoring
Network monitoring
Network monitoring
Network monitoring
Each node has 3 LED indicators showing:
Network
Network
Network
Network
Network
Master
Master
Master
Master
Master
Flashing -
The network is initialising. If it does not cease to flash, there is a cabling fault -
either a double ring error or a problem with one of the cable connectors.
Steady -
This node has become the hub master for this unit. It is either directly connected
to the network master, or connected to a ring which contains the network master.
Off -
This node is slaving to the master's clock.
Sync
Sync
Sync
Sync
Sync
Steady
- This indicates the presence of a valid network connection on this node.
Flashing -
There is a problem with the incoming network signal - possibly the maximum
cable length has been exceeded.
Activity
Activity
Activity
Activity
Activity
Flashing
- This LED indicates data transfer. The flashing is not regular, but dependant on
the rate of transfer.
The node 1 light also indicates RS232 serial messaging in the same manner.
DSP Clip
DSP Clip
DSP Clip
DSP Clip
DSP Clip
Illuminated
- Indicates that the signal is clipping internally.
Power
Power
Power
Power
Power
Steady
- This indicates that the power supply is functioning.
RX - 5
GND - 4
TX - 3
RTS - 1
CTS - 2
Front panel details
RS232
RS232
RS232
RS232
RS232
Used to connect one of the 9000 units in the network to a controller PC, which can then
communicate with any device on the network. The pin out is:
Control cable wiring details
All control connections to the 9000 are via Klippon pluggable terminal block connectors
(also known as BL, Phoenix or Combicon). 6-way female Klippon connectors are
supplied for making these connections.