35
7.0
RECALL
RECALL
Quick Reference
1
Press RECALL.
2
Turn the Parameter control to select a program
number.
3
Press RECALL a second time to load the EQ into the
current device.
RECALL is used to load any of the 50 stored programs within a
Varicurve device into the current program and filter hardware. If the
user wishes to browse through several stored equalisation programs
then please
refer to the Section 8.0 ‘COMPARE’.
The first press of the RECALL button changes the Program box in the
status bar to indicate the source program number and its associated
name. The equalisation display will change to show the equalisation
curve stored in the chosen program but the device filters will not be
altered at this stage. Turn the Parameter control to choose a program
number. As each program is selected, its curve will be displayed.
Only those programs which have been stored in the same access
mode as the current access mode will be available. The Parameter
control will skip over all others.
Omnidrive programs cannot be recalled from the FPC-900R.
Once a program has been chosen press Recall a second time. The
filters in the current device will then be updated with the equalisation
data. The new program number is now displayed in large characters in
the Program box in the status bar. If the recalled equalisation is now
altered in any way, the program number will change to small
characters indicating that the current EQ no longer matches the stored
data. Recalling a Room Curve will send new filter parameters to the
current Device but not Program changes.
To leave the function at any time before Recalling any data, press the
Speed Strip or select another key.
A full list of the programs already Stored in the device is available by
pressing INDEX after the first press of RECALL. Adjusting the source
program number with Index on will move the cursor within the index.
Locked programs are indicated with a key symbol.
To recall a stored program from another device into the current device,
press RECALL followed by the Device key for the device from which
you wish to copy. You can now choose a program to Recall from the
selected device. To finish, press RECALL a second time.
Recalling Between Devices
INDEX in Recall Mode
NOTE:
NOTE:
7.1 INDEX in Recall
mode.
7.2 Recalling
Between Devices
Содержание FPC900r
Страница 1: ...1 FPC900r User Manual...
Страница 74: ...VARICURVE 7 4 TM S Y S T E M User Notes...
Страница 75: ...75 User Notes...
Страница 76: ...VARICURVE 7 6 TM S Y S T E M User Notes...
Страница 77: ...77 User Notes...
Страница 78: ...VARICURVE 7 8 TM S Y S T E M User Notes...