Water Supply
The performance of any unvented system is only as good as the mains water supply available. To this
effect the maximum possible water demand should be assessed, with the knowledge that the mains
supplies both hot and cold services simultaneously. The water heater itself operates at a pressure
of 3bar, controlled by the inlet control set, and is capable of delivering over 50 litres per minute. The high
quality inlet control set has been designed to make the most of the low rates available.
The water supply should be checked to ensure it can meet these requirements. If necessary, consult
the local water authority regarding the likely pressure and flow rate availability.
Consideration should be given to upgrading existing 1⁄2” (15mm) cold mains pipework to a larger
size if the recommended minimum pressure / flow rate is not being achieved. BSS recommend that
primary pipework used has a minimum diameter of 22mm to ensure low pressure loss.
A high static (no flow) mains pressure is no guarantee of good flow availability. In a
domestic installation 1.5bar and 25ltr/min should be regarded as the minimum. The
maximum mains pressure that the inlet control set can cope with is 10bar.
Change Of Water Supply
The changing or alternating from one water supply to another can have a detrimental effect on the
operation and/or life expectation of the water heater storage cylinder, pressure temperature relief
valve and heating unit.
Where there is a changeover from one water supply to another, e.g. a rainwater tank supply, bore
water supply, desalinated water supply, public reticulated water supply or water brought in from
another supply, then water chemistry information should be sought from the supplier or it should
be tested to ensure the water supply meets the requirements given in these guidelines for the BSS
warranty to apply.
Water Chemistry
This water heater must be installed in accordance with this advice to be covered by the BSS warranty.
This water heater is manufactured to suit the water conditions of most public reticulated water supplies.
However, there are some known water chemistries which can have detrimental effects on the water
heater and its operation and/or life expectancy. If you are unsure of your water chemistry, you may be
able to obtain information from your local water supply authority.
Содержание BOSS 100
Страница 4: ...www bssindustrial co uk 4 ...
Страница 31: ...Boss Direct Indirect Installation Guide 31 Cylinder Schematic Electrical Diagram S Plan ...
Страница 33: ...Boss Direct Indirect Installation Guide 33 Cylinder Schematic Electrical Diagram Y Plan ...
Страница 44: ...www bssindustrial co uk 44 48 Direct Indirect Mains Pressure Benchmark Checklist ...
Страница 45: ...Boss Direct Indirect Installation Guide 45 49 Water Storage System Commisioning ...
Страница 47: ...Boss Direct Indirect Installation Guide 47 Notes ...