NetSetter may come up with the wrong network adapter selected to
communicate with. In the upper left hand corner there is a drop down
menu that will list the IP addresses your computer has. Select the IP
address that begins with 169.254 the last two numbers will vary. If you do
not see that address as one of the options, please verify that your network
is enabled and the cables are connected.
6�
If the HiQnet Contrio Server is not found, please check your firewall
settings to verify that HiQnet NetSetter is not being blocked and repeat the
process again.
7�
After selecting the network interface, wait up to one minute while the
software discovers the address of the Contrio Server. Once it has been
discovered, it will appear in the table within NetSetter. The Status column
should say 'Discovered' if everything is correct. If the status column does
not say 'Discovered', ensure that the DHCP/Auto-IP is checked for the
server. If it is not, click to enable it and then at the bottom of the window
click Apply Current Edits
8�
Next move the LAN cable to
, wait approximately 90 seconds and
then choose ‘Rescan Network’ in NetSetter. You should then configure
your
port accordingly. This is most likely your Dante port, so choose
the settings appropriate to Dante operation. When finished, click Apply
Current Edits to accept changes.
9�
You have now established communication between your computer
and the server. There is one more piece of configuration that Harman
recommends.