SAVIO PLUS COMBI USER MANUAL

2.  Technical Information Cont.

ENERGY CAPACITY

Nominal heat input 
(0/2000ft)

MBH

116.0

Nominal heat input 
(2000/4500ft)

MBH

110.2

Minimum heat input

MBH

49.5

Maximum useful output 
(0/2000ft)

MBH

102.0

Maximum useful output 
(2000/4500ft)

MBH

97.2

Minimum useful output

MBH

41.6

GAS SUPPLY PRESSURE

Gas

Normal

Min

Max

Natural

inwc

7.0

3.5

10.5

Propane

inwc

11.0

8.0

13.0

GAS PRESSURE AT BURNER

Gas

Min

Max

Ignition

Natural

inwc

1.0

4.8

2.4

Propane

inwc

2.0

10.3

5.2

FLUE DESIGN

Minimum Venturi pressure

inwc

0.64

Flue pipe diameter

Coaxial

in

2.25/4
3.25/5

Twin split pipes

in

3.25/3.25

Nominal heat 

fl

 ow rate

MBH

116.0

Nominal heat 

fl

 ow rate 

(2000/4500ft)

MBH

110.2

Min Exhaust temperature

°F

1

20

Max Exhaust temperature

°F

1

90

GAS FLOW RATE

Gas

Min

Max

Natural

ft³/h

48.7

115.1

Propane

lb/h

2.2

5.2

CLEARANCE TO COMBUSTIBLES

Front

in

18

Back

in

0

Top

in

8

Sides

in

2

Bottom

in

8

Flue pipe enclosed

in

2

Flue pipe free air

in

0

Hot water pipes

in

1”

FLUE GAS FIGURES

Gas

Min

Max

CO

2

2.5%

6.3%

O

2

16.5%

9.7%

DOMESTIC HOT WATER

Maximum temperature

°F

131

Minimum temperature

°F

95

Maximum pressure

psi

145

Minimum pressure

psi

4.35

D.h.w. 

Δ

T 25K

gal/h

4.5

D.h.w. 

Δ

T 30 K

gal/h

3.8

D.h.w. 

Δ

T 35 K

gal/h

3.2

D.h.w. 

Δ

T 40 K

gal/h

2.8

Содержание Savio plus combi

Страница 1: ...light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Fol low the gas supplier s instructions If you can...

Страница 2: ...installing contractor is the best judge of a system s specific requirements as well as the local availability of certain makes and models of controls and accessories The preceding does not apply howev...

Страница 3: ...Operation Lights 4 10 Instructions for Use 5 11 14 Warnings 5 1 11 Refilling Procedure 5 2 11 Lighting Operation Instruction 5 3 12 Central Heating Circuit Temp 5 4 12 13 Extinguishing Instructions 5...

Страница 4: ...alified service technician to inspect the boiler and to replace any part of the control system and any gas control which has been under water Do not store or use gasoline or other flammable vapors and...

Страница 5: ...ten confused with those of influenza and the highest incidence of poisoning occurs at the onset of cold weather or during flu season A victim may not experience any symptoms only one symptom or a few...

Страница 6: ...boiler area clean and free of all fire hazards Please read the literature and warranties supplied by the manufacturers of the various accessory equipment This equipment is warranted by the respective...

Страница 7: ...al frost protection system to prevent frost dam age which can occur in areas susceptible to very cold weather conditions Boiler operation recognition system should the boiler not be used for longer th...

Страница 8: ...ressure inwc 0 64 Flue pipe diameter Coaxial in 2 25 4 3 25 5 Twin split pipes in 3 25 3 25 Nominal heat flow rate MBH 116 0 Nominal heat flow rate 2000 4500ft MBH 110 2 Min Exhaust temperature F 120...

Страница 9: ...tton 7 Function switch and Central heating tem perature adjustment knob 8 Domestic hot water temperature control knob 9 Appliance operation lights 4 5 6 7 8 9 3 1 2 Figure 3 1 Figure 3 3 Figure 3 2 Pi...

Страница 10: ...n Anti freeze system active 1 second pulse every 2 seconds normally operating boiler Function selector in on position Central heating operation Frost protect operation Faulty central heating temperatu...

Страница 11: ...h a built in anti freeze system that operates the boiler when the temperature is below 41 F Therefore when the boiler is not lit or used in cold weather with consequent risk of freezing do not switch...

Страница 12: ...s operating boiler 4 If the appliance will not operate follow the extinguishing instructions on page 13 and call your service technician or gas supplier Figure 5 2 A B C D E Central Heating Circuit Te...

Страница 13: ...F Between 23 and 41 F Lower than 23 F Extinguishing Instructions 5 5 To turn the boiler off set the function selector B to the position shown in the Figure 5 5 The appliance operation light A figure...

Страница 14: ...minimum output Where the demand is at a low level or with the temperature set to the minimum it is normal to see a cycle of lighting and extinguishing of the burner when running Regulate the domestic...

Страница 15: ...the external temperature may be lower than 32 F it is suggested to leave the system running setting the room thermostat at a low temperature When the boiler is completely switched off for a long perio...

Страница 16: ...n and then press the boiler reset button 2 Fig 6 2 For the first light up and following main tenance procedures for the gas supply it may be necessary to repeat the resetting operation several times s...

Страница 17: ...that this does not happen and to decrease the pressure to a normal value it is advisable to vent some of the water in the appliance through the bleed valves present in the heating system Figure 6 3 If...

Страница 18: ...ight pre paid BOYERTOWN and SAVIO will not be responsible for 1 Components that are part of the heating system but were not manufactured by SAVIO or BOYERTOWN as part of the boiler 2 The workmanship o...

Страница 19: ...SAVIO PLUS COMBI USER MANUAL 19...

Страница 20: ...17962 1520 0 2908 20A4 USA...

Отзывы: