bsg Savio plus combi Скачать руководство пользователя страница 5

SAVIO PLUS COMBI USER MANUAL 

5

WARNING

Any appliance that burns natural gas, propane gas, fuel oil, wood or coal is capable of pro-
ducing carbon monoxide (CO). Carbon Monoxide (CO) is a gas which is odorless, colorless 
and tasteless but is very toxic. CO is lighter than air and thus may travel throughout the 
building.

BRIEF EXPOSURE TO HIGH CONCENTRATIONS OF CO, OR PROLONGED EXPO-

SURE TO LESSER AMOUNTS OF CO MAY RESULT IN CARBON MONOXIDE POISON-

ING. EXPOSURE CAN BE FATAL AND EXPOSURE TO HIGH CONCENTRATIONS MAY 

RESULT IN THE SUDDEN ONSET OF SYMPTOMS INCLUDING UNCONSCIOUSNESS.

Symptoms of CO poisoning include the following:
 

dizziness 

vision problems 

shortness of breath

 

headache 

loss of muscle control 

unclear thinking

 nausea 

weakness 

unconsciousness

The symptoms of CO poisoning are often confused with those of in

fl

 uenza, and the highest 

incidence of poisoning occurs at the onset of cold weather or during 

fl

 u season.

A victim may not experience any symptoms, only one symptom, or a few symptoms.

Suspect the presence of carbon monoxide if symptoms tend to disappear when you 
leave your home.

The following signs may indicate the presence of carbon monoxide:

Hot gasses from appliance, venting system pipes or chimney, escaping into the living 

• 

space.
Flames coming out around the appliance.

• 

Yellow colored 

fl

 ames in the appliance.

• 

Stale or smelly air.

• 

The presence of soot or carbon in or around the appliance.

• 

Very high unexplained humidity inside the building.

• 

If any of the symptoms of CO occur, or if any of the signs of carbon monoxide are
present, 

VACATE THE PREMISES IMMEDIATELY AND CONTACT A QUALIFIED

HEATING SERVICE COMPANY OR THE GAS COMPANY OR THE FIRE
DEPARTMENT.

ONLY QUALIFIED, LICENSED SERVICE CONTRACTORS SHOULD PERFORM WORK 
ON YOUR SAVIO SAVIO PLUS COMBI BOILER.

Содержание Savio plus combi

Страница 1: ...light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Fol low the gas supplier s instructions If you can...

Страница 2: ...installing contractor is the best judge of a system s specific requirements as well as the local availability of certain makes and models of controls and accessories The preceding does not apply howev...

Страница 3: ...Operation Lights 4 10 Instructions for Use 5 11 14 Warnings 5 1 11 Refilling Procedure 5 2 11 Lighting Operation Instruction 5 3 12 Central Heating Circuit Temp 5 4 12 13 Extinguishing Instructions 5...

Страница 4: ...alified service technician to inspect the boiler and to replace any part of the control system and any gas control which has been under water Do not store or use gasoline or other flammable vapors and...

Страница 5: ...ten confused with those of influenza and the highest incidence of poisoning occurs at the onset of cold weather or during flu season A victim may not experience any symptoms only one symptom or a few...

Страница 6: ...boiler area clean and free of all fire hazards Please read the literature and warranties supplied by the manufacturers of the various accessory equipment This equipment is warranted by the respective...

Страница 7: ...al frost protection system to prevent frost dam age which can occur in areas susceptible to very cold weather conditions Boiler operation recognition system should the boiler not be used for longer th...

Страница 8: ...ressure inwc 0 64 Flue pipe diameter Coaxial in 2 25 4 3 25 5 Twin split pipes in 3 25 3 25 Nominal heat flow rate MBH 116 0 Nominal heat flow rate 2000 4500ft MBH 110 2 Min Exhaust temperature F 120...

Страница 9: ...tton 7 Function switch and Central heating tem perature adjustment knob 8 Domestic hot water temperature control knob 9 Appliance operation lights 4 5 6 7 8 9 3 1 2 Figure 3 1 Figure 3 3 Figure 3 2 Pi...

Страница 10: ...n Anti freeze system active 1 second pulse every 2 seconds normally operating boiler Function selector in on position Central heating operation Frost protect operation Faulty central heating temperatu...

Страница 11: ...h a built in anti freeze system that operates the boiler when the temperature is below 41 F Therefore when the boiler is not lit or used in cold weather with consequent risk of freezing do not switch...

Страница 12: ...s operating boiler 4 If the appliance will not operate follow the extinguishing instructions on page 13 and call your service technician or gas supplier Figure 5 2 A B C D E Central Heating Circuit Te...

Страница 13: ...F Between 23 and 41 F Lower than 23 F Extinguishing Instructions 5 5 To turn the boiler off set the function selector B to the position shown in the Figure 5 5 The appliance operation light A figure...

Страница 14: ...minimum output Where the demand is at a low level or with the temperature set to the minimum it is normal to see a cycle of lighting and extinguishing of the burner when running Regulate the domestic...

Страница 15: ...the external temperature may be lower than 32 F it is suggested to leave the system running setting the room thermostat at a low temperature When the boiler is completely switched off for a long perio...

Страница 16: ...n and then press the boiler reset button 2 Fig 6 2 For the first light up and following main tenance procedures for the gas supply it may be necessary to repeat the resetting operation several times s...

Страница 17: ...that this does not happen and to decrease the pressure to a normal value it is advisable to vent some of the water in the appliance through the bleed valves present in the heating system Figure 6 3 If...

Страница 18: ...ight pre paid BOYERTOWN and SAVIO will not be responsible for 1 Components that are part of the heating system but were not manufactured by SAVIO or BOYERTOWN as part of the boiler 2 The workmanship o...

Страница 19: ...SAVIO PLUS COMBI USER MANUAL 19...

Страница 20: ...17962 1520 0 2908 20A4 USA...

Отзывы: