PROBLEM

 

POSSIBLE CAUSE

 

SOLUTION

 

Axial fan does not 

start

 

No electricity.

 

Check for power supply.

 

The power cord is not properly 

plugged in.

 

Remove and reconnect the 

power cord.

 

The circuit breaker on the 

additional electrical receptacle 

(Daisy chain) jumps.

 

Remove all appliance on 

the additional electrical

 

receptacle and press “Reset”.

 

Unit runs but the 

speed is abnormal

 

Air inlet or air outlet is blocked.

 

Remove blockage.

 

 

If troubleshooting does not resolve your problem, please contact your local 

distributor, or BSE direct for further instructions.

 

User Maintenance Instructions 

(Continued)

 

Stack Multiple Units

 

Stack the axial units on their sides. Align the 

air inlets of both axial units.

 

!

 

WARNING

 

Do not stack more than six units of this 

appliance.

 

Stacking function is not secure during

transportation.

 

Troubleshooting Guide

 

Содержание P-1100

Страница 1: ...Commercial Air Mover Axial Fan Owner s Manual Model P 1100 115V 60HZ Read before use and save these instructions for future reference Rev 7 20 20...

Страница 2: ...control device DO NOT touch this appliance or the plug with wet hands or while standing in water DO NOT operate the appliance in any pooled water DO NOT use the product in areas where gasoline paint...

Страница 3: ...apacitor 6 Housing Handle 7 Switch Plate 8 Rack Handle 9 Rubber Washer 10 Rack 11 Fan 12 Rear End Cover 13 Rear Grille Cover 14 Power Cord 15 Transformer not shown 16 Ionizer not shown Items Included...

Страница 4: ...in classrooms hotel rooms service vehicles and more 2 3 1 4 OFF Speed Control Speed Switch Turn to OFF position to switch the axial unit OFF Turn to any speed position to switch the axial unit ON Tur...

Страница 5: ...k whether the axial unit is on or off However the total amperage must be lower than the amperage instructed Different models may have varying instructions If the axial unit or the plugged in appliance...

Страница 6: ...sconnect the Axial Fan from its power source Use a damp cloth to wipe the surface of the housing Do not clean the unit with water directly IONIZER CLEANING As needed carefully clean the ion generating...

Страница 7: ...prevent possible injury when you finish using this appliance please position the Axial Fan UPRIGHT Fasten the rack handle to lock the position of the Axial Fan Organize the Power Cord Wrap the power c...

Страница 8: ...eceptacle and press Reset Unit runs but the speed is abnormal Air inlet or air outlet is blocked Remove blockage If troubleshooting does not resolve your problem please contact your local distributor...

Страница 9: ...V 60 Hz Amperage 0 6 A Rated Airflow 1100 CFM Speed Control 4 Speeds Additional Electrical Receptacles Daisy Chain Yes Cord Length 10 ft Housing Polypropylene Unit Dimensions L x W x H 16 1 x 8 9 x 1...

Страница 10: ...problems with electrical power supply 3 2 Disassembling servicing or modification not authorized by distributor or end user 3 3 Usage that is not accordant with product instructions stated in Owner s...

Страница 11: ...ber on the shipping label or the packaging 3 Include all of the original parts and components Distributor or BSE will inspect assess and advise the repairs needed and applicable cost if any For produc...

Страница 12: ......

Отзывы: