background image

WARNING 

Ensure the correct rotary direction if the motor to avoid damage the pump and vacuum 

system. 

 

1.  Observe the cooling fan from the fan cover of the motor. 

2.  Turn on the motor for several minutes then turn it off. 

3.  Check whether the cooling fan of the motor rotates in the direction shown by the arrow 

on the motor mounting plate. If the direction is not correct, 

Cut off the power 

Remove cap of terminal box and exchange any two of L1, L2, L3. Then back the cap. 

Turn on the pump and check the rotary direction of fan. 

4.6   

The connection between air inlet of the pump and user’s system 

Use  VG80  standard  pipe  joint  to connect  the  pump  with  user

’s system. Pay attention to 

following points 

 

  In order to achieve the best pumping speed, make sure that the pipe connecting with 

air  inlet  should  be  as  short  as  possible  and  less  elbow  exist.  The  internal  diameter 

should be smaller than that of air inlet. 

 

  Hold the vacuum pipes steadily in case of too much stress on the joints 

 

  If  it

’s  necessary,  use  soft  bellows  to  reduce  the  vibration  and  stress  on  joints.  The 

withstanding pressure of soft bellows should be higher than the maximum pressure 

produced by the vacuum system. If the pump is installed on the shock absorber, the 

soft bellows must be used. 

 

  Use  proper  valves  to  separate  the  pump  from  user

’s  system  if  vacuum  status  is 

needed with the pump off. 

 

  Equip with the filter on air inlet of the pump if the pump is used for the exhausting and 

inhaling of condensing steam or placed in dusty occasion. 

 

  Ensure that the surface of seals are clean and free of scratch. 

 

 

4.7    The 

connection between gas outlet and user’s system 

 

Содержание BSV175

Страница 1: ...ion 4 2 Overview of the System 4 3 Cooling Water Piping 4 4 Oiling 4 5 Electrical Wiring 4 6 Gas Inlet 4 7 Gas Outlet 4 8 Gas Ballast 4 9 Leakage Testing 5 Operation 5 1 Starting 5 2 The Controller of...

Страница 2: ...efore maintenance and inspection The non professional personnel shall not disassemble repair or alter the vacuum pump Otherwise the failure may cause fire and injury as well as the abnormal operation...

Страница 3: ...eep adequate ventilation to avoid the rising of temperature causing burn and fire Do not touch the vacuum pump when it s working or just halted for the surface temperature can reach 80 C Please take s...

Страница 4: ...he oil inlet pipe and is inhaled into the spring distribution valve The valve will distributes a little pressurized oil into the vacuum chamber and will transport redundant oil to the storage cavity b...

Страница 5: ...g plug screw 8 Draining plug screw 3 The gas ballast valve 9 Cooling water outlet G3 8 4 Discharge vent 10 Cooling water inlet G3 8 5 Oil return port is for external oil filter 11 Motor terminal 6 Oil...

Страница 6: ...s ballasting off 5 10 1 5 10 1 Pa Gas ballasting on 2 2 Pa Maximum outlet pressure full flow Psig 0 5 0 5 bar Psia 1 5 105 1 5 105 Pa Air inlet Flange with O ring VG80 VG80 DN Air outlet Flange with O...

Страница 7: ...3 3 Mounting Dimensions Figure 3 BSV175 BSV275 installation drawing...

Страница 8: ...equipment when conveyed The vacuum pump should be installed on a horizontal stable platform Ensure that it s easy access to the oiling plug screw and draining plug screw as well as has a well sight of...

Страница 9: ...fer to figure 1 for the following numbers 1 Remove the oiling plug screw 2 Oil the pump till the max level on sight glass 6 Drain the redundant oil through Draining plug screw 8 3 Check the oil level...

Страница 10: ...ly restart when power restores after interrupted The adoption of manual reset electric control device does not lead to automatically restart of the pump We recommend that the use of motor connected wi...

Страница 11: ...e the best pumping speed make sure that the pipe connecting with air inlet should be as short as possible and less elbow exist The internal diameter should be smaller than that of air inlet Hold the v...

Страница 12: ...tion that the inlet pressure exceeds 1000Pa for long In the situation that the pump starts working at atm Oil mist filter will trap the oil in the pump If the oil is not contaminated it can be reused...

Страница 13: ...low vacuum section Using gas ballast controller can prevents steam inside of pump from condensing which would lead contamination to the pump Close the gas ballast controller by clockwise rotation Ope...

Страница 14: ...he maintenance job must be completed by trained technical personnel in the condition that obey the national and local safety regulations 2 Ensure that the maintenance personnel are familiar with the s...

Страница 15: ...nd clean air inlet filter Every year Clear the cover of motor Every year Clean and overhaul the pump Every year Test the motor Every year Replace the vanes Every 3 years Table 2 Maintenance plan 6 3 C...

Страница 16: ...system 3 Remove the filter from air inlet 4 Clean the filter in proper cleaning solution then dry it 5 Position the filter on air inlet 6 Reconnect the pump with the vacuum system 7 Reconnect the powe...

Страница 17: ...trictly before shipment and the warranty lasts 1 year since the date of delivery Any breakdown out of quality happens during the warranty our company is responsible for free repair and replacement 8 2...

Страница 18: ...Intake pipe diameter is too small or too long Make the correct configuration of the air inlet pipe The leakage of vacuum system and pipes Block the leakage Air inlet filter blocked Clean the air inle...

Страница 19: ...taminated or inappropriate Replace the pump oil Insufficient oil quantity Replenish pump oil Discharge filter or pipe blocked Clean discharge filter or pipe High temperature of inhaled gas Lower the t...

Страница 20: ...inder O ring A 111 AS568 FKM 1 O ring A 114 AS568 FKM 1 O ring A 216 AS568 FKM 2 O ring A 331 AS568 FKM 1 O ring A 341 AS568 FKM 1 O ring 132 2 M FKM 1 O ring 165 2 M FKM 2 O ring S9 JIS FKM 2 O ring...

Страница 21: ...bnormal motion Oil leakage Others Description Others 2 service condition Used or not YES NO Utility time 24hr service Interval service Contaminate or not YES NO Product name and chemical name of the c...