2.
Technical Data
2.1 Operating and storage conditions
Note: Operating in the temperature range of -10 to 5 °C, we recommend that the pump be
operated continuously in addition to the necessary shutdown maintenance. In addition,
attention should be paid to the requirements for cooling water proposed in Section 2.6.
Due to the flexibility of the hydraulic drive, the range of backing pumps that can be used
with the pump is wide. The environmental conditions for operation and storage are shown in
the table below.
Ambient operating temperature and humidity
Ambient storage temperature and humidity
Altitude
5 to 40
℃
, below 90%RH
-10 to 50
℃
, below 90%RH
Below 1000m
Table.1 Operating and storage conditions
2.2 Performance
Rotational speed:
50Hz power supply
60Hz power supply
Maximum outlet pressure
0 to 2950 r/min
0 to 3560 r/min
1000 mbar absolute (1×10
5
Pa)
Pressure differential ( determined by the hydraulic drive):
BSJ600LC
50Hz power supply
60Hz power supply
BSJ1200LC
50Hz power supply
60Hz power supply
0 to 80 mbar (0 to 8×10
3
Pa)
0 to 67 mbar (0 to 6.7×10
3
Pa)
0 to 70 mbar (0 to 7×10
3
Pa)
0 to 50 mbar (0 to 5×10
3
Pa)
Table.2 Performance
2.3 Mechanical data
Dimensional drawing
See Fig.1
Weight
BSJ600LC 350 kg
BSJ1200LC 425 kg
Table.3 Mechanical data