4 EMERGENCY HANDWHEEL OPERATION

AQ actuators feature a handwheel for emergency operation.
To avoid potentially harmful turning protruding parts during 

electrical operation, AQ handwheels feature a foldable handle: you

can fold it during electrical operation and unfold it if you need to 

operate the actuator manually. 

5 ELECTRICAL COMMISSIONNING

Connection and preliminary tests

8

 - Capacitor

7

 - Switches board

6

 - Torque limiter

5

 - Motor

4

 – Heating resistance

3

 - Cams

2

 - Terminal block

1

 - Position indicator

Actuator and its components are wired to internal terminal blocks.
To proceed to the wiring, remove the cover and pass the cables 

through the M20 cable entries or ¾” NPT cable entries

(depending on order).
Please refer to the wiring diagram enclosed for terminal numbering.
Both thermal protector and torque limit switches must be integrated 
into your control system in order to prevent potential damage to the

actuator or valve.

  

7

Содержание 215.3842.6.11 171.8093.1L.13

Страница 1: ...1 AQ SWITCH RANGE Start Up Guide Instructions de mise en service SUG_17003 Ind A Art 5100466...

Страница 2: ...on 4 EMERGENCY HANDWHEEL OPERATION 6 5 ELECTRICAL COMMISSIONNING 6 5 1 Connection and preliminary tests 5 2 Position feedback potentiometer OPTION 5 3 TAM position transmitter OPTION 5 4 Heating resis...

Страница 3: ...Avoid placing the actuator directly on the floor Check that plugs on cable entries are correctly tightened Check that cover screws are correctly tightened to ensure weatherproof sealing of the cover...

Страница 4: ...not in service increases the risk of malfunction This is not advisable If a long term storage is absolutely necessary we strongly recommend a revision of the electronic boards in our factory before a...

Страница 5: ...be oriented upwards loss of water tightness Changing closing direction indication As a standard AQ actuator is configured to close clockwise If the actuator must close counter clockwise you can change...

Страница 6: ...nd preliminary tests 8 Capacitor 7 Switches board 6 Torque limiter 5 Motor 4 Heating resistance 3 Cams 2 Terminal block 1 Position indicator Actuator and its components are wired to internal terminal...

Страница 7: ...nd check that the motor rotates in the right direction 5 Manually press on the counter clockwise travel limit switch then the motor should stop 6 Repeat steps 4 and 5 for clockwise direction If any fa...

Страница 8: ...eases then turn backwards to reach the closest value to 0 Ohm Tighten back the positioner pinion blocking screw 4 Drive the actuator to the OPEN position and write down the resistance value correspond...

Страница 9: ...Maximum admissible resistance values are given in the following table DC supply volts Max admissible resistance ohms 12 150 24 750 32 1050 Signal direction inversion The TAM transmitter when supplied...

Страница 10: ...stop as soon as the minimum value determined here above is reached and tighten back the potentiometer pinion blocking screw The potentiometer is then positioned at the very beginning of its track 6 Th...

Страница 11: ...for a 90 travel It features 2 devices to limit the travel Cams trigger switches to switch off power at an end position or to signal a position Mechanical stops mechanically block rotation to protect t...

Страница 12: ...osition when the travel limit switch is tripped Travel limit settings The mechanical stops 1 counter clockwise 2 clockwise avoid over travel in case of handwheel operation They can be set on the actua...

Страница 13: ...the cam corresponding to clockwise travel limit switch Clockwise signaling switch cam setting if wired 6 Drive slightly the output in the counter clockwise direction using manual override 7 Set the ca...

Страница 14: ...ue limiter operation Please check below torque limiter setting components 5 Clockwise direction cam 4 Clockwise direction switch 3 Counter clockwise direction cam 2 Counter clockwise direction switch...

Страница 15: ...BERNARD CONTROLS BENELUX NIVELLES BRUSSELS inquiry belgium bernardcontrols com inquiry holland bernardcontrols com Tel 32 0 2 343 41 22 FRANCE BERNARD CONTROLS FRANCE BERNARD CONTROLS NUCLEAR FRANCE G...

Отзывы: