STEP 3 - Connect the battery charger to mains power 

• 

Connect the battery charger to a mains powered socket.

• 

Turn on the mains power.

Once the connection instructions have been followed, AC power is presented, power White LED ON. The charger will begin charging 

automatically, the “Charging” Blue LED is ON. When full charge is reached, the “Maintaining” “Full” Green LED will be ON. The Main-

taining Float Mode allows the charger to effectively be left connected to your batteries, over the course of a season for Lead acid 

batteries, without overcharging your batteries and maintains your battery’s full charge, for a LiFePo4 battery, it will automatically 

terminate the charge if the battery fully charged and Green LED will be ON. 

STEP 4 - Disconnecting the Bank charger from Battery

Switch OFF and Remove the AC Power Socket from the outlet; Remove the Black lead and then the Red lead. Check electrolyte levels 

if possible. (As they may need topping up with distilled water after charging)

CHARGING PROCESS

 

 

The bank charger provides the multiple charging phases subjected to the Lead acid battery sensed or LiFePO4 battery sensed.

Force mode stage

Press the Force mode for 3 seconds: the bank charger will activate the low voltage “dead” Lead acid battery and engage de-sulpha-

tion; it will wake up the “dead” LiFePO4 battery where the under-voltage protection has been triggered.

Soft start

In this phase rising voltage and a maximum of 50% of bulk phase current is applied to the battery to start the charging cycle.

Bulk stage

In this phase rising voltage and maximum output current is applied to the battery. 

Analysis-1 Stage

In this phase the band charger tests the battery in order to detect bad cells (only for Lead acid batteries). For abnormal cell detection 

results please refer to the troubleshooting section.

Absorption stage

In this phase a constant voltage and tapering current is applied to the battery to ensure it reaches 85% state of charge. 

Analysis- 2 Stage

In this phase the charger tests the battery again in order to detect bad cells and high levels of sulphation (only for Lead acid batteries) 

Float and Maintenance

Compatible only with Lead Acid batteries this stage is used for long term battery maintenance.

Float returns to Bulk charging

When battery voltage is dropped below 12.5V.

LiFePo4 Recharge phase

If the battery voltage falls below 12.8V; the bank charger will automatically return to Bulk phase.

Voltages are set for 12V mode, x 1/2 for 6V mode.

CHARGE CURVE

 

 

ONLY FOR LEAD ACID*

FOR LEAD ACID & LITHIUM

Battery

detection

Reconditioning

1

or wake-up

2

Soft start

Bulk 1

Analysis 1

Bulk 2

Absorption

Analysis 2

Maintenance

Float

VOLTAGE

(V)

CURRENT

(Amps)

10

* Only if force mode is selected:

- For lead acid: reconditioning stage.

- For lithium: wake-up stage.

** No float & maintenance stages for Lithium. Once the battery is fully charged, the charge is stopped.

Содержание BK 20

Страница 1: ...ALE D USO 11 ES MANUAL DE USUARIO 15 DE BENUTZERHANDBUCH 19 PT MANUAL DO UTILIZADOR 23 Release 2021 07 www bs battery com SMART BANK BATTERY CHARGER MAINTAINER WITH RECONDITIONING FUNCTION 3 CHANNELS...

Страница 2: ...CLIP CLIP BOX CONTENT 3x Clamps sets 140 cm 1x AC plug EU 150 cm 1x CHARGER Q UICK CONNECTI O N DESIGNED FOR WORKSHOPS WAREHOUSES...

Страница 3: ...it is not supposed to be used by children or by people who are not able to understand the manual unless they are supervised by a responsible person who ensures the proper use of the kit MAIN FEATURES...

Страница 4: ...ficiency 80 Charging stage Multiple 10 stages Start voltage 2 0V for 6V mode 8V for 12V mode Charging voltage 14 4V De sulphation I peak 0 2A De sulphation V max 16V Float voltage Lead acid battery 13...

Страница 5: ...he under voltage protection has been triggered Soft start In this phase rising voltage and a maximum of 50 of bulk phase current is applied to the battery to start the charging cycle Bulk stage In thi...

Страница 6: ...cator lights on No AC power Check AC connections and make sure Power Point is swit ched ON Charger has no DC output Fault LED is On Output is short cir cuited Reverse polarity connection to Battery Ch...

Страница 7: ...out entretien ou nettoyage Ce chargeur n est pas cens tre utilis par des enfants ou par des personnes qui ne sont pas en mesure de comprendre le manuel moins qu ils ne soient supervis s par une person...

Страница 8: ...ent nerg tique 80 Etage de charge Multiple 10 stages Tension de d marrage 2V pour le mode 6V 8V pour le mode 12V Tension de charge 14 4V D sulfatation I pic 0 2A D sulfatation V max 16V Tension flotta...

Страница 9: ...iqu s la batterie pour d marrer le cycle de charge Etape pleine charge Dans cette tape une tension croissante et un courant de sortie maximal sont appliqu s la batterie Etape d analyse 1 Dans cette ph...

Страница 10: ...on secteur non branch e V rifier la bonne connexion du chargeur au secteur et v rifier si la prise fonctionne correc tement La charge ne d marre pas LED d faut est clair e Mauvais branchement de la ba...

Страница 11: ...Disattivare i controlli per ridurre ogni rischio Il kit non dovrebbe essere utilizzato da bambini o da persone che non sono in grado di capire il manuale a meno che non siano sorvegliate da una perso...

Страница 12: ...e 6 12 V 2 Amp x 3 bande Adatto al tipo di batteria Compatibile con le batterie al piombo acido o LiFePO4 Efficienza energetica 80 Fasi di carica Multiple 10 fasi Tensione iniziale 2 0 V per la modali...

Страница 13: ...nteeunmassimodel50 dellacorrentedellafasedicaricaprincipale Fase di carica principale In questa fase si applica alla batteria una tensione crescente e la massima corrente di uscita Fase di analisi 1 I...

Страница 14: ...Nessuna alimentazione CA Controllare le connessioni CA e assicurarsi che la presa di corrente sia attiva Il caricatore non ha CC in uscita Il LED di guasto acceso L uscita in corto circuito Inversion...

Страница 15: ...el riesgo El kit no debe ser utilizado por ni os o por personas que no sean capaces de entender este manual salvo que est n supervisadas por una persona responsable que garantice el uso correcto del...

Страница 16: ...ra el modo 12 V Tensi n de carga 14 4V Pico de intensidad de desulfataci n 0 2 A Tensi n m xima de desulfataci n 16 V Tensi n de flotaci n Bater as de plomo cido 13 6V Tensi n de mantenimiento Bater a...

Страница 17: ...la corriente de la fase inicial bulk para iniciar el ciclo de carga Etapa inicial bulk En esta fase se aplica a la bater a una tensi n creciente y una corriente de salida m xima Etapa An lisis 1 En es...

Страница 18: ...las conexiones de CA y aseg rese de que el punto de alimentaci n est encendido El cargador no tiene salida de corriente continua El led de fallo est encendido La salida est cortocircuitada Polaridad...

Страница 19: ...e beim Umgang mit Blei S ure Batterien keinen metallischen Schmuck wie Ringe Halsketten Armbanduhren etc Rauchen Sie niemals in der Umgebung von Motoren und Batterien Vermeiden Sie Funkenbildung und o...

Страница 20: ...bel mit Blei S ure oder LiFePO4 Batterien Wirkungsgrad 80 Aufladestufen Mehrere 10 Stufen Startspannung 2 0 V bei 6 V Modus 8 V bei 12 V Modus Ladespannung 14 4V Entsulfatierung ISpitze 0 2 A Entsulfa...

Страница 21: ...nesteigendeSpannungundmaximal50 desHauptladestromsandieBatterieangelegt umdenLadezykluszustarten Hauptladephase In dieser Phase wird eine steigende Spannung und ein maximaler Ausgangsstrom an die Batt...

Страница 22: ...d stellen Sie sicher dass die Stromquelle aktiviert ist Ladeger t hat keine Gleichstro mausgabe St rungs LED leuchtet Ausgang ist kurzgeschlossen Verpolter Anschluss an Batterie Pr fen Sie die Wechsel...

Страница 23: ...risco O kit n o deve ser utilizado por crian as ou por pessoas que n o s o capazes de entender o manual a menos que sejam super visionadas por uma pessoa respons vel que garanta o seu uso correto CARA...

Страница 24: ...ncia energ tica 80 Fase de carregamento M ltiplas 10 fases Tens o inicial 2 0 V para o modo de 6 V 8 V para o modo de 12 V Tens o de carregamento 14 4 V Dessulfata o I ponto m ximo 0 2 A Dessulfata o...

Страница 25: ...cio suave Nesta fase aplicada bateria uma tens o crescente e um m ximo de 50 da corrente da fase em massa para iniciar o ciclo de carga Fase em massa Nesta fase aplicada bateria uma tens o crescente e...

Страница 26: ...carregador n o funciona Sem luzes indi cadoras ligadas Sem energia CA Verifique as liga es CA e certifique se de que o Power Point est LIGADO O carregador n o tem sa da de CC O LED de falha est Ligad...

Страница 27: ...www bs battery com...

Страница 28: ...polarity short circuit and internal overheat protection Easy to use connect forget Multiaxis hook SMART BATTERY CHARGER 12V 3A MAINTAINER For Lead Acid Lithium Smart battery charger maintainer Auto d...

Отзывы: