Room Calibration
Dirac Live®
6
Introduction
Setup
Measure
Optimize
Export
34
6.9) Once all measurements are completed, you will be able to visualise magnitude and impulse
responses of all speakers. In addition, Dirac Live
®
will add the recommended target curve as well
as the window of correction deduced from the measurements. In this Quick Guide, we will follow
Dirac Live
®
recommendation to proceed. Shall you need to customize these two elements, please
refer to the
StormAudio_Dirac Live CT_Installer_Manual_rev 2.pdf
to find the descriptions of
all the adjustments options available.
1.
The orange Target Curve can be
adjusted by moving the markers
and markers can be added by double
clicking on the curve at the needed
frequency.
Auto Target will recall the Dirac Live
®
recommended curve.
You can Save and Load your own
created Target Curve.
2.
It is possible to limit the correction to a certain
frequency range in order to avoid low frequency
correction in speakers limited or not capable in this
area. The same applies in high frequency. By default
correction window is kept full frequency spectrum.
3.
Keeping the recommended curve and
correction window, you can launch
the Optimization.
1
2
i
i
3