background image

STRIPPED BARE WIRE 

up to 3 gauge can be inserted through the hole in the binding post and held in place by 

tightening the post knob. Additional tightening pressure can be achieved using the wrench provided in the slots 

of the knob. Do not over tighten or the binding post may become damaged. Note that copper wire is malleable 

and should not be initially over-tightened or the connection may eventually become lose and require further tight-

ening.

D

 

EXTERNAL ZONE MUTE CONNECTOR:

 

When any or all of the 4 zone mute pins (labelled "1", "2", "3" & "4") are connected to the common pin (Labelled "C") 

the corresponding Zone will be muted. 

10

 

STEREO BUS INPUTS:

There are two pair of daisy-chained RCA connectors for single-ended 

bus

 inputs. An input signal connected to one 

Left input will appear at the other Left input connector.  Likewise, an input signal connected to either Right Stereo 

Bus Input will be present on the other Right Stereo Bus Input. This input has 20K Ohms input impedance.

REMOTE POWER TURN-ON

 

(LOCAL/EXTERNAL SWITCH)

To power-up the D65/130/250Z using an external control voltage supply a 4v to 

12v  AC or DC control voltage (at approximately 2mA minimum) to the ‘IN’ termi-

nals of the “Power-Up” connector.  The front panel ‘Power’ switch needs to be off 

for remote operation.

Use paired wire of 22 gauge to 18 gauge between the source device and the 

D65/130/250Z. The amplifier will now power-up when the control voltage is pres-

ent.  

Immediately following power up, the control voltage will appear at the ’OUT’ termi-

nals of the “Power-Up” connector for the control of other equipment.

Removal of the control voltage causes the D65/130/250Z to turn ‘off’ and the con-

trol voltage at the ‘OUT’ terminals is interrupted.

NOTE:

 

The ‘OUT’ terminals of the “Power-Up” connector are connected to the ‘IN’ terminals once the D65/130/250Z 

has powered-up. 

NOTE: 

Each channel normally mutes momentarily during power up and power down sequences.

AC POWER INPUT

This is a high current plug for the power cord receptacle. Check that the voltage rating at the right of the connector con-

forms with your locality. With the front panel power switch in the off position, insert the power cord into the D65/130/250Z, 

then plug the other end to an appropriate A/C power outlet. 

The control current across the “OUT” terminals is determined by the 

source 

equipment. The carrying current of the 

‘OUT’ relay is 2 amps. The D65/130/250Z itself draws less than 3 mA from the control current when operating.  The 

D65/130/250Z channel LED, when unlit, indicates no A/C mains power is present at the channel. If all channel LED 

indicaors are unlit the D65/130/250Z probably needs only to be powered on. A group of 4 LEDs not lighting possibly indi-

cates a blown group fuse. When checking fuses, unplug the power cord. Use on the specified fuses for your operating 

voltage.  

See FUSES section on page 2.

D65Z 

 D130Z 

 D250Z 

 

8 CHANNEL POWER AMPLIFIERS    

A/C POWER CONTROL

Содержание D65Z

Страница 1: ...OWNER S MANUAL D65Z D130Z D250Z ...

Страница 2: ...g defects for twenty 20 years from the original date of manufacture The warranty includes parts and labour Bryston Digital products and cables are warranted for five years from the original date of manufacture The warranty includes parts and labour Bryston products having motorized moving parts excluding motorized volume controls are warranted for three years from the original date of manu facture...

Страница 3: ...ch LED Indicators Rear Panel Fuses Power Inlet Remote Power Turn On Connector Page 3 Remote Power Turn On Switch Channel Level Control Channel Direct Inputs Input Selector Switches Output Binding Posts Speaker Connectors External Zone Mutes Page 4 Stereo Bus Inputs AC Power Control External Control Voltage Power Up AC Power Input Technical Specifications Page 5 D65Z D130Z D250Z 8 CHANNEL POWER AMP...

Страница 4: ... a cabinet it should have an open front and back Should your installation conditions be constricted then additional forced air cooling may be necessary Any D65 130 250Z channels thermally shutting down during operation indicates insufficient cooling and a remedy must be found for cooling the amplifier Provide a minimum 6 space to the rear of the D65 130 250Z for ventilation and dressing cables to ...

Страница 5: ...to be taken to increase airflow across the channels heat sink See installation section on ventilation on page 1 CLIPPING occurs when the channel output level no longer can follow the level increase at the input Over driven input condition When a D65 130 250Z channel is driven into clipping the channel LED will change from green to red then back to green when the level is reduced will appear to be ...

Страница 6: ...ce 20K Ohms B INPUT SELECTOR SWITCHES These four position slide switches select the input signals for each channel independantly Position Description 1st top Left bus from STEREO BUS INPUTS item 10 2nd sum of left and right STEREO BUS INPUTS item 10 3rd Right bus from STEREO BUS INPUTS item 10 4th bottom direct input from RCA jack C OUTPUT BINDING POSTS The RED binding post is connected to the amp...

Страница 7: ...30 250Z The amplifier will now power up when the control voltage is pres ent Immediately following power up the control voltage will appear at the OUT termi nals of the Power Up connector for the control of other equipment Removal of the control voltage causes the D65 130 250Z to turn off and the con trol voltage at the OUT terminals is interrupted NOTE The OUT terminals of the Power Up connector ...

Страница 8: ...STON LTD 677 NEAL DRIVE P O BOX 2170 PETERBOROUGH ONTARIO CANADA K9J 7Y4 2011 04 27 1 Output Power Nominal output power levels are limited by the amount of current the D130 D250 is allowed to draw form a residential branch circuit Power output from individual channels or from groups of channels can be much higher when only some channels are driven to high power levels Note that each of the two zon...

Отзывы: