![Bryston BP-17 cubed series Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/bryston/bp-17-cubed-series/bp-17-cubed-series_owners-manual_2823090006.webp)
6
IR Control
You may control the BP-17³ with a traditional
infrared remote control such as Bryston’s BR2.
To use a Bryston BR2 with the BP-17³, press the
PREAMP button. Volume and Mute remain active
even when the remote is in D/A or CD mode.
1
2
3
OPTO-1
OPTO-2
SPDIF-2
SPDIF-3
SPDIF-1
UP-SAMPLE
7
0
8
9
USB
SPDIF-4
AES/EBU
FORWARD
PLAY
REPEAT
PAUSE
RANDOM
NEXT
EJECT
STOP
TIME
BACK
SCAN
PREVIOUS
CD
D/A
BR2
4
5
6
CODE
POWER
USB
OPTO-1
OPTO-2
SPDIF-2
SPDIF-3
SPDIF-4
SPDIF-1
AES/EBU
FORWARD
PLAY
REPEAT
PAUSE
UP-SAMPLE
RANDOM
NEXT
EJECT
STOP
TIME
BACK
SCAN
PREVIOUS
CD
D/A
BR2
1
4
7
0
2
5
8
3
6
9
CODE
POWER
PREAMP
PREAMP
A/D
A/D
Aux/Ph
Aux/Ph
CD
CD
Tuner
Tuner
TV
TV
Video
Video
D1
D1
D2
D2
D3
D3
D4
D4
Phase
Phase
Rec
Rec
VOLUME
MUTE
MUTE
VOLUME
To configure the BR-2 for control over the BP-17³,
execute the following steps:
1. Press and hold the CODE button on the BR2
remote until the red LED begins to flash (usually
takes about 5 seconds).
2.
As soon as the LED remains steadily RED, release
the CODE button and enter the the 3 digit code
712 before the LED goes out. The LED will flash
twice after a valid code has been successfully
entered.
Inputs 1-4, Balanced Input 1 and Balanced Input
2 can be selected by pressing the buttons that
correspond with 1-6 where 5 and 6 select Balanced
Input 1 and Balanced Input 2 respectively. Digital
inputs D1-D4, Record Monitor, Balance L/R are
marked in blue.
Special codes such as those used for bypass or
trigger assignment can be sent by pressing the
CODE button once, then entering the 3 digit code.
HEX codes for use with universal remote controls
are available from Bryston upon request.
Trigger Control
The BP-17³ can control the power state of other
attached devices. Two DC trigger outputs are
provided. Each is a tip/sleeve (mono mini plug) and
is wired with the tip at V
DC
and sleeve ground.
Trigger 1 will commonly be used to trigger the
attached amplifier(s) on or into standby as it is not
source dependent. When the BP-17³ is powered on,
voltage is present at the tip of this connector and is
removed when the unit is placed into standby.
Trigger 2 can be configured to activate based on
a selected source. Voltage is present at the tip of
this connector when a specific source is selected.
For instance, if a BCD-3 CD player is connected to
Balanced Input 1, you may wish to configure Trigger
2 to activate on when Balanced Input 1 is selected.
To assign Trigger 2 to an input, select that input and
issue the command 247 using the BR-2 or RS232.
Issue command 248 to clear Trigger 2 from that
input.