Optional Modules

The BP-17³ may be optionally equipped with a 

moving magnet phono input and/or a digital to 

analog converter. These may be fitted at the time 

of ordering or retrofit at a later time by a certified 

technician.

Moving Magnet Phono

The optional MM Phono input occupies INPUT 2, so 

input 2 can no longer be used for line level source 

components such as tuners, CD players, etc. This 

high quality phono stage is the same circuit found in 

our stand alone BP-2 MM. 

Digital to Analog Converter (DAC)

The DAC is a high quality module that shares INPUT 

1. That is, INPUT 1 can still operate as a standard 

analog stereo input pair, but it can also operate as 

two separate S/PDIF digital coaxial inputs. When 

the DAC module is installed, digital inputs 1 and 2 

(TOSLINK optical connectors) are also connected 

and activated. In total, when the DAC is installed, 4 

digital inputs are available for use. To select a DAC 

input, press the DIGITAL 

 

SELECT button on the 

front panel or the BR-2 remote control, then press 

the button that corresponds with the input you wish 

to hear. The DAC can receive PCM digital audio at 

44.1kHz, 48kHz, 88.2kHz, or 96kHz sampling rates 

and 16 or 24 bit resolution. When a digital input is 

activated, the LED above 1 will illuminate green. The 

LED above the selected digital input will illuminate 

red when the input is selected and green when it 

is selected locked to a compatible digital audio 

source. Each input will remember whether analog 

or digital was last selected.

Remote Control

The BP-17³ can be controlled and monitored 

through RS232 and IR. 

Serial Protocol

The BP-17³ can receive commands, send 

acknowledgment of commands received, and can 

be queried for certain statuses. 

Using the DB9 female connector at the rear of the 

unit, the BP17 can receive commands via a straight-

through cable at 9600 baud, 8 data bits, no parity 

and 1 stop bit (9600,8,N,1). Valid commands will 

return the “>” character indicating that the unit 

is ready to receive a new command. An invalid 

command will return the “!” character.

These serial data commands are as follows: 

Category

Cmd. Description

Power

000

Power Off

029

Power On

015

Toggle On/Off

Volume

007

Volume Up

008 Volume Down

009

Toggle Mute

058

Mute On

059 Mute Off

950 Query current master level

4xx

Discrete volume set where xx=00 

to 80 (0dB to -80dB)

Source

001 Input 1

002 Input 2 / Phono

003 Input 3

004 Input 4

005 Balanced Input 1

006

Balanced Input 2

061

Toggle Record Monitor

062

Record Monitor On

063 Record Monitor Off

081

Digital Input 1

082

Digital Input 2

083

Digital Input 3

084

Digital Input 4

245 Toggle Home Theater Bypass 

(unity gain) for current input

Balance

019 Balance Left

020 Balance Right

955 Query balance left/right levels

Trigger

247 Set Trigger 2 for current input

248

Clear Trigger 2 for current input

System

255 Default system settings

990 returns model, serial, and rev 

numbers and date code

Содержание BP-17 cubed series

Страница 1: ...BP 17 Cubed Series Preamplifier Owner s Manual...

Страница 2: ...sale from a Bryston authorized dealer to qualify for warranty service The warranty is transferable from the original owner to a subsequent owner as long as a copy of the bill of sale from the origina...

Страница 3: ...nstallation 4 Ventilation 4 Connecting to A C Power 4 Connecting to Audio Components 4 Connecting Source Components 4 Connecting Amplification 4 Optional Modules 5 Moving Magnet Phono 5 Digital to Ana...

Страница 4: ...erial as the unit is not insurable by carriers otherwise Replacement packing materials consisting of a shipping carton with plastic foam inserts is available from Bryston for a small fee Installation...

Страница 5: ...en the input is selected and green when it is selected locked to a compatible digital audio source Each input will remember whether analog or digital was last selected Remote Control The BP 17 can be...

Страница 6: ...and Balanced Input 2 can be selected by pressing the buttons that correspond with 1 6 where 5 and 6 select Balanced Input 1 and Balanced Input 2 respectively Digital inputs D1 D4 Record Monitor Balan...

Страница 7: ...T 102 dB 108 dB Input Impedance Unbalanced Balanced non inverting Balanced inverting 6 5 k 4 5k 4 5k Gain RCA IN RCA rec out RCA IN RCA preamp out XLR IN XLR fixed out XLR IN XLR preamp out 0dB 12dB M...

Страница 8: ...analog source components When the BP 17 is fitted with the optional DAC module 5 analog inputs are available plus 4 digital inputs When the BP 17 is fitted with the optional MM Phono module 5 line lev...

Страница 9: ...efeated Rear Panel 10 Output Section The BP 17 is equipped with 4 stereo analog outputs Balanced Output 1 Variable output Pin 1 GND Pin 2 Positive Pin 3 Negative configurable as fixed output at time o...

Страница 10: ...mplifier to power on and operate Only replace the fuse with one of identical value Do not attempt removal or replacement of the fuse when the amplifier is plugged into the wall 16 Data Plate Unit spec...

Страница 11: ...BP 17 Cubed Series Preamplifier 11 This page intentionally left blank...

Страница 12: ...Bryston Limited 677 Neal Drive Peterborough Ontario K9J 6X7 Canada Phone 705 742 5325 www bryston com 08 28 2017 300068 5...

Отзывы: