and normal operation. Use the front panel 

push-button power switch or an external 

control voltage to power-up or power-down 

the amplifier. Should the breaker trip, or switch 

“OFF”,  lower or remove the amplifier input 

signals. Remove the AC power by disconnecting 

the power cord from the amplifier for 20 

seconds. Switch the breaker to the ‘ON’ position. 

Reconnect the power cord, then power the unit 

up normally. The circuit breaker must be ‘ON’ 

at all times for the Cubed Series amplifier to 

operate.

6. A/C Power Input: 

An IEC-320 C14 power inlet provides for 

connection of an IEC-320 C13 equipped power 

cord.  Before connecting the power cord to the 

amplifier, check that the voltage rating on the 

data plate or ratings label conforms with your 

locality. With the circuit breaker ‘ON’ insert the 

power cord into the Cubed series amplifier, then 

plug the other end to an appropriate A/C outlet.

7. Remote Power Up:

When in External position, the Power On state 

is governed by voltage applied to IN terminals 

of the Remote Power Up connector. The front 

panel power switch must remain in the ‘ON’ 

position. “External Control Voltage” on page 

6 for instructions regarding connection and 

usage.

8. Power Status Indicator:

Plugging in the power cord applies power to 

the amplifier. The status indicator will initially 

flash green. The number of flashes indicates the 

revision of the soft start circuit software. This 

puts the amplifier in Standby mode and the LED 

turns red indicating power is present.

Engaging  the front panel on/off switch initializes 

the startup sequence. During the soft start ramp 

up, operation the status led will turn orange 

when connected to 60Hz power or red when 

connected to 50Hz power. The Status LED 

switches to green when the ramp up sequence 

ends then turns off ten seconds later. Turning 

off the front panel on/off switch returns the 

amplifier to the Standby mode.

9. Data Plate:

Unit specific information is printed here 

including model number, operating voltage, 

frequency, and serial number. 

28B3 -17-SIL-120 

~120V   60Hz   2200W

Serial No:      28B3-000000

Date: 1530     REV:1234      

Содержание 28B3

Страница 1: ...28B3 Amplifier Owner s Manual ...

Страница 2: ...AIN READILY OPERABLE BRYSTON LIMITED WARRANTY Bryston analog audio products are warranted to be free from manufacturing defects for twenty 20 years from the original date of manufacture The warranty includes parts and labour Bryston digital products and cables are warranted for five years from the original date of manufacture The warranty includes parts and labour Bryston products having motorized...

Страница 3: ...Description 4 Features 4 Shipping Box and Packing Material 4 Installation and Usage 4 Ventilation 4 Connecting to A C Power 4 Connecting to Loudspeakers 5 Balanced vs Single Ended Input 6 Power Conditioners 6 Front Panel 7 Rear Panel 8 28B3 Specifications 10 Dimensions 11 ...

Страница 4: ...ise Replacement packing materials consisting of a shipping carton with plastic foam inserts is available from Bryston for a small fee Installation and Usage Ventilation Bryston has deliberately chosen to omit fans from our amplifiers in an effort to minimize the noise level in your listening environment Instead we use only passive heat sinks which are fully capable of maintaining a safe operating ...

Страница 5: ... be kept as short as practical and should never be terminated with connectors that may become confused for AC power connectors Cables should be dressed away from input and power cables Banana plugs offer a quick disconnect option Before inserting a banana plug into the binding post be sure to tighten the post nut to avoid rattling and to provide full insertion of the banana plug Gold plated lockin...

Страница 6: ...ision and clarity External Control Voltage To power up the amplifier using an external control voltage supply a 5V to 12V AC or DC control voltage to the IN terminals of connector fig 1 Use paired wire of 22 to 18 gauge between the source device and the Bryston Cubed series amplifier The appropriate mating connector is supplied with each amplifier Set the External Turn On switch to External See 7 ...

Страница 7: ...ccurs when the channel output level no longer can follow the level increase at the input over driven input condition When a channel is driven into clipping the channel LED will change from green to red then back to green when the level is reduced Momentary clipping can be tolerated however it indicates that maximum undistorted power has been surpassed and potential speaker damage may result if ove...

Страница 8: ... wire Combinations may be used when bi wiring Cables should be kept as short as practical and should never be terminated with connectors that may become confused for AC power connectors Cables should be dressed away from input and power cables Only use Class 2 Rated Wiring No other wiring is permitted for use 5 Master Circuit Breaker The Cubed series amplifier uses a magnetic trip circuit breaker ...

Страница 9: ...n the Power On state is governed by voltage applied to IN terminals of the Remote Power Up connector The front panel power switch must remain in the ON position External Control Voltage on page 6 for instructions regarding connection and usage 8 Power Status Indicator Plugging in the power cord applies power to the amplifier The status indicator will initially flash green The number of flashes ind...

Страница 10: ...nded Balanced Balanced 15kΩ 15kΩ 15kΩ IMD 60Hz 7kHz 4 1 0 005 THD N 20Hz 20kHz 1000W 8Ω 0 005 Noise input shorted 22Hz 22kHz Single Ended Balanced 116dB 117dB Slew Rate 65V µS Bandwidth 1Hz to 100kHz 3dB Damping 20Hz 8Ω 300 Weight Pounds Kilograms 93 42 Power Consumption Watts Standby Idle 1000W 8Ω 166W 8Ω 0 5 225 1790 810 Heat Load BTU Hour Idle 1000W 8Ω 166W 8Ω 768 6108 2764 ...

Страница 11: ...28B3 Amplifier 11 8 1 in 7 8 in 7 in 4U 17 in 19 in 19 in 18 4 in 16 8 in Dimensions Minimum recommended clearance for heat dissipation 17 C Series 19 C Series includes front handles ...

Страница 12: ...Bryston Limited 677 Neal Drive Peterborough Ontario K9J 6X7 Canada Phone 705 742 5325 www bryston com 300046 2016 02 04 ...

Отзывы: