Bryston 28B3 Скачать руководство пользователя страница 7

28B

3

 Amplifier

7

1. Power/Standby Switch:

The front panel features a push-on/push-off 

type latching power switch used to apply or 

remove A/C line power to the SoftStart circuitry. 

Note that the rear circuit breaker must be on for 

the amplifier to power-up.

2. LED Indicator: 

The amplifier channel has a front panel LED 

indicator to monitor the following conditions:

Unlit

Amplifier not powered on (OFF 

MODE)

Red

Channel is muted during power up

Green

Channel operation is normal

Flashing 

Red

Channel is clipping. Reduce input 

level!

Orange

Thermal protection mode

POWER UP SEQUENCE

 

After pushing the power switch, each channel 

LED will turn from unlit to red (mute). When the 

power supplies have stabilized, the channel will 

come out of mute and the LED will change to 

green (normal operation).

UNLIT LED

  (No power)

 

The amplifier channel LED when unlit indicates 

no A/C mains power is present at the channel 

power transformer. This usually indicates 

that the amplifier probably needs only to be 

powered on.

CLIPPING

 (flashing red)

 

Clipping occurs when the channel output level 

no longer can follow the level increase at the 

input (over driven input condition). When a 

channel is driven into clipping, the channel 

LED will change from green to red then back to 

green when the level is reduced. Momentary 

clipping can be tolerated, however it indicates 

that maximum undistorted power has been 

surpassed and potential speaker damage 

may result if overload conditions persist. Any 

amplifier that is constantly operated into 

clipping indicates a more powerful amplifier is 

needed for that application.

THERMAL SHUTDOWN

 (orange)

 

Each channel has thermal shutdown circuitry 

to prevent damage due to overheating.  Should 

thermal shutdown occur, the channel will mute, 

and the channel LED will turn orange. When 

the channel has cooled to a safe operating 

condition, the channel will return to normal 

operation. Persistent thermal shutdown 

indicates steps need to be taken to increase 

airflow across the channel or channels heat 

sink. See “Ventilation” on page 4.

In some markets the LED indicators, which are  

normally red/green, may be red/blue instead. 

When red/blue LEDs are supplied green is 

replaced with blue and orange is replaced with 

magenta in the above descriptions.

Front Panel

1

2

Содержание 28B3

Страница 1: ...28B3 Amplifier Owner s Manual ...

Страница 2: ...AIN READILY OPERABLE BRYSTON LIMITED WARRANTY Bryston analog audio products are warranted to be free from manufacturing defects for twenty 20 years from the original date of manufacture The warranty includes parts and labour Bryston digital products and cables are warranted for five years from the original date of manufacture The warranty includes parts and labour Bryston products having motorized...

Страница 3: ...Description 4 Features 4 Shipping Box and Packing Material 4 Installation and Usage 4 Ventilation 4 Connecting to A C Power 4 Connecting to Loudspeakers 5 Balanced vs Single Ended Input 6 Power Conditioners 6 Front Panel 7 Rear Panel 8 28B3 Specifications 10 Dimensions 11 ...

Страница 4: ...ise Replacement packing materials consisting of a shipping carton with plastic foam inserts is available from Bryston for a small fee Installation and Usage Ventilation Bryston has deliberately chosen to omit fans from our amplifiers in an effort to minimize the noise level in your listening environment Instead we use only passive heat sinks which are fully capable of maintaining a safe operating ...

Страница 5: ... be kept as short as practical and should never be terminated with connectors that may become confused for AC power connectors Cables should be dressed away from input and power cables Banana plugs offer a quick disconnect option Before inserting a banana plug into the binding post be sure to tighten the post nut to avoid rattling and to provide full insertion of the banana plug Gold plated lockin...

Страница 6: ...ision and clarity External Control Voltage To power up the amplifier using an external control voltage supply a 5V to 12V AC or DC control voltage to the IN terminals of connector fig 1 Use paired wire of 22 to 18 gauge between the source device and the Bryston Cubed series amplifier The appropriate mating connector is supplied with each amplifier Set the External Turn On switch to External See 7 ...

Страница 7: ...ccurs when the channel output level no longer can follow the level increase at the input over driven input condition When a channel is driven into clipping the channel LED will change from green to red then back to green when the level is reduced Momentary clipping can be tolerated however it indicates that maximum undistorted power has been surpassed and potential speaker damage may result if ove...

Страница 8: ... wire Combinations may be used when bi wiring Cables should be kept as short as practical and should never be terminated with connectors that may become confused for AC power connectors Cables should be dressed away from input and power cables Only use Class 2 Rated Wiring No other wiring is permitted for use 5 Master Circuit Breaker The Cubed series amplifier uses a magnetic trip circuit breaker ...

Страница 9: ...n the Power On state is governed by voltage applied to IN terminals of the Remote Power Up connector The front panel power switch must remain in the ON position External Control Voltage on page 6 for instructions regarding connection and usage 8 Power Status Indicator Plugging in the power cord applies power to the amplifier The status indicator will initially flash green The number of flashes ind...

Страница 10: ...nded Balanced Balanced 15kΩ 15kΩ 15kΩ IMD 60Hz 7kHz 4 1 0 005 THD N 20Hz 20kHz 1000W 8Ω 0 005 Noise input shorted 22Hz 22kHz Single Ended Balanced 116dB 117dB Slew Rate 65V µS Bandwidth 1Hz to 100kHz 3dB Damping 20Hz 8Ω 300 Weight Pounds Kilograms 93 42 Power Consumption Watts Standby Idle 1000W 8Ω 166W 8Ω 0 5 225 1790 810 Heat Load BTU Hour Idle 1000W 8Ω 166W 8Ω 768 6108 2764 ...

Страница 11: ...28B3 Amplifier 11 8 1 in 7 8 in 7 in 4U 17 in 19 in 19 in 18 4 in 16 8 in Dimensions Minimum recommended clearance for heat dissipation 17 C Series 19 C Series includes front handles ...

Страница 12: ...Bryston Limited 677 Neal Drive Peterborough Ontario K9J 6X7 Canada Phone 705 742 5325 www bryston com 300046 2016 02 04 ...

Отзывы: