19
Overload Protections:
A & mA
: 0.44A/1000V DC/AC rms, IR 10kA, F fuse
A
: 11A/1000V DC/AC rms, IR 20kA, F fuse
V
: 1100V DC/AC rms
mV,
& Others : 1000V DC/AC rms
E.M.C. : Meets EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2,
EN61000-4-3, EN61000-4-4, , EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11)
In an RF field of 3V/m:
Capacitance function is not specified
Other function ranges:
Total Accuracy = Specified Ac 100 digits
Performance above 3V/m is not specified
Power Supply: Single 9V battery; NEDA1604G, JIS006P IEC6F22, NEDA1604A, JIS6AM6
or IEC6LF22
Power Consumption: 5 mA typical
APO Timing: Idle for 30 minutes
APO Consumption: 50
A typical
Dimension: L208mm X W103mm X H64.5mm with holster
Weight: 635 gm with holster
Accessories: Test lead pair; battery installed; user’s manual; BKP60 banana plug type-K
thermocouple
(Models 829s, 827s, 521s & 525s
only)
Optional purchase accessories: USB interface kit BU-86X; BKB32 banana plug to type-K
socket plug adaptor
Electrical Specifications
Accuracy is
(% reading number of digits) or otherwise specified, at 23
o
C
5
o
C &
less than 75% relative humidity.
True RMS voltage & current accuracies are specified from 10 % to 100 % of range or
otherwise specified. Maximum Crest Factor < 2:1 at full scale & < 4:1 at half scale, and with
frequency components within the specified frequency bandwidth for non-sinusoidal
waveforms.