Proper Rotation detection relies on solid signal connection to all three test lead terminals
simultaneously. Any single disconnection will lead to detection failure and may produce false
indication. To verify signal connection and hence proper meter indication, swap any two
connects (to the meter) to check for meter indication of reverse movement
Connect to the Motor as illust rated. Be sure the electricity supply is removed. From the
perspective of looking down the shaft of the motor, speed
spin it clockwise to generate
sufficient signal strength for proper meter detection. If the meter indicates a clockwise
movement, the motor leads connected to L1, L2 and L3 of the meter are L1, L2 and L3 (also
known as R, S and T) respectively. If the meter indicates a counter clockwise movement,
swap any two connects between the meter and motor. Then retest.
Connect to the MAINS as illustrated.
If the meter indicates a clockwise movement, the
phases connected to L1, L2 and L3 of the meter are L1, L2 and L3 (also known as R, S and
T) respectively. If the meter indicates a counterclockwise movement, swap any two
connects between the meter and phases. Then retest. Connect the above mentioned L1, L2
and L3 of a Motor and that of the MAINS respectively should
be able to get a clockwise
motor movement.
:
The Complementary Beeper feature is selected in Power up option. Press and hold the
button while turning the meter on to enable. If the segments indicate a clockwise movement,
the beeper sounds a single long beep per segment cycle. If t he segments indicate a counter
clockwise movement, the beeper sounds 3 short beeps per segment cycle.
Press
button momentarily to activate MAX/MIN /AVG
MIN AVG turn on. The meter beeps when new MAX (maximum) or MIN (minimum) reading
is updated. Press the button momentarily to read the MAX, MIN, AVG readings in sequence.
Press the button for 1 second or more to exit MAX/MIN /AVG recording mode. Auto ranging
remains, and AutoPowerOff is disabled automatically in this mode.
Press the
button for 1 second or more to toggle the LCD backlight. The backlight
will also be turned off automatically after 10 minutes to extend battery life.