FACTORY--INSTALLED OPTIONS (FIOPs)

j

Economizer with D

RY

B

ULB

sensing and barometric

relief*

Standard Air Leak Dampers —

f

Models with W7212 controller provides standard

non--diagnostic control. EconoMi$er IV.

f

Models with W7220 controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements. EconoMi$er X.

f

Models with RTU Open controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements. EconoMi$er 2.

j

Economizer with E

NTHALPY

sensing and barometric

relief*

Standard Air Leak Dampers —

f

Models with W7212 controller provides standard

non--diagnostic control. EconoMi$er IV.

f

Models with W7220 controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements. EconoMi$er X.

f

Models with RTU Open controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements. EconoMi$er 2.

j

Economizer with D

RY

B

ULB

sensing and barometric

relief*

ULTRA LOW LEAK Air Dampers —

f

Models with W7220 controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements, has return, outside

air and relief damper leakage that meets Title 24

(section 140.4 and ASHRAE 90.1) requirements --

plus 5 year limited parts warranty. EconoMi$er X.

f

Models with RTU Open controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements, has return, outside

air and relief damper leakage that meets Title 24

(section 140.4 and ASHRAE 90.1) requirements --

plus 5 year limited parts warranty. EconoMi$er 2.

j

Economizer with E

NTHALPY

sensing and barometric

relief*

ULTRA LOW LEAK Air Dampers —

f

Models with W7220 controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements, has return, outside

air and relief damper leakage that meets Title 24

(section 140.4 and ASHRAE 90.1) requirements --

plus 5 year limited parts warranty. EconoMi$er X.

f

Models with RTU Open controller meets California

Title 24 (section 120.2) Fault Detection and

Diagnostic (FDD) requirements, has return, outside

air and relief damper leakage that meets Title 24

(section 140.4 and ASHRAE 90.1) requirements --

plus 5 year limited parts warranty. EconoMi$er 2.

j

RTU Open multi--protocol controller communicates to

LON, MODBUS, BACNET and Johnson N2 protocols.

j

Through the base connectors for gas and electric

conduit/piping

j

Stainless steel gas heat exchanger (includes tubes,

vestibule plate and collector box)

j

Perfect Humidity

t

dehumidification system*

j

2 position motorized outdoor air damper*

j

Non--fused disconnect

j

Powered 115--volt convenience outlet*

j

Non--powered 115--volt convenience outlet

j

High static evaporator fan motor

j

Return Air smoke detector

j

Supply Air smoke detector

j

CO

2

sensor

j

Condenser hail guard -- louvered style*

j

Special coating protection for evaporator

and condenser coils*

* Not available for single phase (--J voltage) models.

OPTIONAL WARRANTIES

j

Complete Unit Parts only up to 5 years

j

Complete Unit Parts and Labor up to 5 years
Many other optional warranties are available.

See the

Commercial Start--Up and Optional Extended

Warranty Price

price pages for further information.

580J

Содержание LEGACY 580J

Страница 1: ...down to 20_F 29_C S Field convertible from vertical to horizontal airflow for slab mounting No special kits required S Two inch disposable return air filters S Thru the bottom power and gas entry cap...

Страница 2: ...ition system Standard Parts Warranty S 15 year gas heat exchanger parts Stainless Steel S 10 year gas heat exchanger parts Aluminized S 5 year compressor parts S 1 year parts PERFORMANCE DATA Unit Ope...

Страница 3: ...4 and ASHRAE 90 1 requirements plus 5 year limited parts warranty EconoMi er 2 j Economizer with ENTHALPY sensing and barometric relief ULTRA LOW LEAK Air Dampers f Models with W7220 controller meets...

Страница 4: ...4 section 140 4 and ASHRAE 90 1 requirements EconoMi er 2 j Economizer with ENTHALPY sensing and barometric relief ULTRA LOW LEAK Air Dampers f Models with W7220 controller meets California Title 24 s...

Страница 5: ...5 CERTIFIED DIMENSION 580J 04 07 C08039 580J...

Страница 6: ...6 CERTIFIED DIMENSION 580J 04 07 C08040 580J...

Страница 7: ...CORPORATION 1 DEC 2 DEC 3 DEC ANG MATERIAL AUTHORIZATION NUMBER TITLE 1041738 CURB ASY ROOF ENGINEERING MANUFACTURING 004 007 ENGINEERING REQUIREMENTS SIZE DRAWING NUMBER REV T 005 Y 002 DRAFTER CHEC...

Страница 8: ...or change at any time specifications or designs without notice and without incurring obligations E2014 Bryant Heating Cooling Systems D 7310 W Morris St D Indianapolis IN 46231 Edition Date 06 14 Rep...

Отзывы: