6.3.7.1. Freeze Limits
This setting controls the temperature level to which the loop liquid can
drop before the Geo HP unit will stop operating. See the Geo HP
Installation Instructions for more details. Typically, 26°F is chosen for
open-loop systems using untreated water; and 15°F is chosen for
closed-loop systems using glycol or other anti-freeze solutions. After the
selection is made, touch
SAVE
.
•
Freeze Limits
: 26°F or 15°F. Default = 26°F