—5—

 

GROSS COOLING CAPACITIES (MBH) Continued

 

CFM

 

— Cubic Ft per Minute

 

EWB

 

— Entering Wet Bulb (°F)

 

LWB

 

— Leaving Wet Bulb (°F)

 

TC

 

— Total Cooling Capacity 1000 Btuh

 

SHC

 

— Total Sensible Capacity 1000 Btuh

 

BF

 

— Bypass Factor

 

MBH

 

—1000 Btuh

 

NOTES:

 

1. Contact manufacturer for cooling capacities at conditions other than 

shown in table.

2. Formulas:

Leaving db = entering db — 

Leaving wb = wb corresponding to enthalpy of air leaving coil (h

 

LWB

 

)

h

 

LWB

 

 = h

 

EWB

 

 — 

where h

 

EWB

 

 = enthalpy of air entering coil.

 

UNIT

SIZE

INDOOR COIL

AIR

SATURATED TEMPERATURE LEAVING EVAPORATOR (°F)

30

35

40

45

50

CFM

EWB

TC

SHC

BF

TC

SHC

BF

TC

SHC

BF

TC

SHC

BF

TC

SHC

BF

 

A060
N060
T060

1600

72

101.0

46.7

0.00

90.8

42.2

0.00

80.4

37.6

0.12

69.1

33.0

0.08

56.0

28.0

0.07

67

83.8

49.9

0.07

73.5

45.2

0.07

63.1

40.5

0.06

51.1

35.3

0.06

38.0

29.8

0.08

62

68.7

53.0

0.07

58.2

48.0

0.07

47.7

43.0

0.07

38.2

37.6

0.11

31.6

31.6

0.24

2000

72

113.0

52.2

0.00

102.0

47.4

0.00

90.4

42.6

0.14

77.5

37.5

0.11

63.5

32.3

0.10

67

94.0

56.8

0.10

82.6

51.8

0.10

71.2

46.8

0.09

58.5

41.3

0.10

43.7

35.2

0.11

62

77.0

61.2

0.09

66.0

56.0

0.10

55.1

50.7

0.10

45.0

44.7

0.15

37.3

37.3

0.28

2400

72

123.0

56.6

0.26

111.0

51.6

0.21

98.4

46.7

0.16

84.2

41.2

0.13

69.4

35.8

0.13

67

103.0

62.8

0.13

89.9

57.4

0.13

77.3

52.0

0.12

64.3

46.5

0.12

48.3

40.0

0.14

62

83.0

68.4

0.11

72.2

63.0

0.12

61.4

57.5

0.13

51.1

51.1

0.18

42.5

42.5

0.32

X060

1600

72

106.0

49.0

0.00

94.4

44.0

0.00

83.1

39.0

0.07

71.6

34.3

0.05

58.4

29.1

0.06

67

85.7

51.3

0.05

75.4

46.5

0.05

65.1

41.7

0.05

52.9

36.4

0.05

39.8

30.9

0.07

62

70.8

54.8

0.04

59.6

49.2

0.05

48.4

43.7

0.06

38.0

37.2

0.13

31.1

31.1

0.26

2000

72

116.0

53.7

0.18

105.0

49.2

0.14

94.7

44.7

0.10

81.6

39.5

0.08

67.3

34.0

0.08

67

97.6

59.1

0.07

86.1

54.0

0.07

74.5

48.8

0.07

61.4

43.1

0.07

46.4

36.9

0.09

62

80.0

64.0

0.05

68.4

58.1

0.07

56.8

52.1

0.09

45.0

44.7

0.16

37.4

37.4

0.29

2400

72

128.0

59.4

0.17

116.0

54.4

0.15

104.0

49.4

0.12

89.9

43.9

0.10

74.1

38.0

0.10

67

108.0

66.0

0.09

94.7

60.4

0.09

81.8

54.7

0.10

67.9

48.8

0.10

51.9

42.3

0.11

62

86.4

71.3

0.08

75.0

65.4

0.10

63.6

59.5

0.12

52.1

52.1

0.17

43.3

43.3

0.31

sensible heat cap.

1.09 x CFM

total capacity (Btuh)

4.5 x CFM

 

3. Direct interpolation is permissible. Do not extrapolate.
4. SHC is based on 80°F db temperature of air entering coil. 

Below 80°F db, subtract (Correction Factor x CFM) from SHC. 
Above 80°F db, add (Correction Factor x CFM) to SHC.

5. All data points are based on 10°F superheat leaving coil.
6. Bypass Factor = 0 indicates no psychometric solution. Use bypass 

factor of next lower EWB for approximation.

Interpolation is permissible.
Correction Factor = 1.09 x (1 – BF) x (db – 80)

 

BYPASS
FACTOR

ENTERING AIR DRY BULB TEMPERATURE (°F)

79

78

77

76

75

Under 75

 

81

82

83

84

84

Over 85

 

Correction Factor

 

0.10

0.98

1.96

2.94

3.92

4.91

Use formula 

shown below

0.20

0.87

1.74

2.62

3.49

4.36

0.30

0.76

1.53

2.29

3.05

3.82

Содержание CK5A

Страница 1: ...ith a slope to help ensure proper drainage im proved moisture removal and home comfort Compact Design Unique design offers as much as 2 in less in height to aid in tight installations Brass Inserts Ev...

Страница 2: ...c 014 14 3 16 in 017 17 1 2 in 021 21 in 024 24 1 2 in A Standard N Narrow T Transition W Wide X Max Cap Position A Painted B Embossed M A N U F A C T U R E R CERTIFIED TO ARI AS C O M P L Y I N G W I...

Страница 3: ...B XW036021 B 21 17 5 8 19 3 8 10 1 2 3 4 2 1 8 1 3 8 44 CK5 A B XA042021 B 21 17 5 8 19 3 8 10 1 2 7 8 2 1 8 1 3 8 44 CK5 A B XN042017 B 17 1 2 17 5 8 15 7 8 10 7 8 7 8 2 1 8 1 3 8 43 CK5 A B XT042021...

Страница 4: ...1 0 26 1250 72 72 1 33 0 0 00 64 7 29 9 0 00 57 3 26 8 0 20 49 4 23 7 0 15 40 1 20 3 0 14 67 59 6 35 8 0 14 52 4 32 7 0 14 45 3 29 5 0 13 36 8 25 9 0 13 27 5 22 0 0 15 62 49 0 38 4 0 14 42 0 35 2 0 13...

Страница 5: ...0 13 51 1 51 1 0 18 42 5 42 5 0 32 X060 1600 72 106 0 49 0 0 00 94 4 44 0 0 00 83 1 39 0 0 07 71 6 34 3 0 05 58 4 29 1 0 06 67 85 7 51 3 0 05 75 4 46 5 0 05 65 1 41 7 0 05 52 9 36 4 0 05 39 8 30 9 0 0...

Страница 6: ...4 0 43 A042 T042 1000 1100 1200 1300 1400 WET 0 18 0 21 0 25 0 28 0 32 DRY 0 14 0 16 0 19 0 23 0 24 N042 1000 1100 1200 1300 1400 WET 0 22 0 26 0 30 0 35 0 41 DRY 0 18 0 22 0 26 0 30 0 34 A048 T048 13...

Страница 7: ...7...

Страница 8: ...this manual including Unit Familiarization Maintenance Installation Overview Operating Sequence A large selection of product theory and skills programs is available using popular video based formats...

Отзывы: