background image

1

Product Data

704C

EVOLUTION

t

13 SEER SINGLE--PACKAGED AIR CONDITIONER

SYSTEM WITH PURON

®

(

R--410A

)

REFRIGERANT

2 TO 5 NOMINAL TONS (024--060)

A06047

Unit 704C

Single--Packaged Products with Energy--Saving Features and
Puron

®

refrigerant.

S

13 SEER

S

Low Sound Levels

S

Variable--Speed Blower (Standard)

S

Factory--Installed TXV

FEATURES/BENEFITS

One--piece cooling unit with optional electric heater, low

installation cost, dependable performance and easy maintenance.

Efficient operation

High--efficiency design

with SEERs (Seasonal Energy Efficiency

Ratio) of 13.0.

Puron

®

Environmentally--Sound Refrigerant

is Bryant’s

unique refrigerant designed to help protect the environment.
Puron refrigerant is an HFC refrigerant which does not contain

chlorine that can harm the ozone layer. The most important

advantage of Puron refrigerant is that it has not been banned in
future air conditioning systems as the traditional refrigerant R--22

has been. Puron refrigerant is in service in over 100,000 systems
proving highly reliable, environmentally sound performance.

PerfectHumidity

t

Technology featuring Evolution

t

control

and Variable--Speed Blower motor

that provides greater

comfort, humidity control, and energy efficiency.

Variable--Speed Blower motors

provide better comfort and

energy efficiency. You can expect up to 30 times better

dehumidification; economical constant fan which provides

improved indoor air quality and more even temperatures from

room to room; and reduced indoor noise due to lower air velocity.
In addition, you’ll realize improved installation flexibility with 3

different airflow choices for best overall comfort.

Easy installation

Factory--assembled package

is a compact, fully self--contained,

electric cooling unit that is pre--wired, pre--piped, and

pre--charged for minimum installation expense. 704C units are
available in a variety of standard capacity ranges with voltage

options to meet residential and light commercial requirements.
Units install easily on a rooftop or at ground level.

Durable, dependable components

Compressors

are designed for high efficiency. Each compressor

is hermetically sealed against contamination to help promote
longer life and dependable operation. Vibration isolation provides

quiet operation. Compressors have internal high--pressure and
overcurrent protection.

Convertible duct configuration

Unit is designed for easy use in either downflow or horizontal

applications. Each unit is easily converted from horizontal to
downflow and includes horizontal duct covers.

Direct--drive, variable--speed blower motor

is standard on all

704C models.

Direct--drive, PSC condenser fan motors

are designed to help

reduce energy consumption and provide for cooling operation
down to 55

°

F outdoor temperature. Motormaster

®

II

low--ambient kit is available as a field--installed accessory.

Evolution

t

User Interface

designed to work as a system with

Bryant’s single--packaged product.

Refrigerant system

is designed to provide dependability. Liquid

refrigerant filter driers are used to promote clean, unrestricted

operation. Each unit leaves the factory with a full Puron
refrigerant charge. Refrigerant service connections make checking

operating pressures easier.

Indoor and outdoor coils

are computer designed for optimum

heat transfer and cooling efficiency. The indoor coil is fabricated

from copper tube and aluminum fins and is located inside the unit
for protection against damage. The outdoor coil is internally

mounted on the top tier of the unit. Copper fin coils and
pre--coated fin coils are available from the factory by special

order. These coils are recommended in applications where

aluminum fins are likely to be damaged due to corrosion. They
are ideal for seacoast applications.

Thermostatic Expansion Valve

—A hard--shutoff, balance--port

TXV maintains a constant superheat at the evaporator exit

(cooling cycle) resulting in higher overall system efficiency.

High-- and Low--Pressure Switches

give added safety and

reliability to the compressor.

Low sound ratings

ensure a quiet indoor and outdoor

environment with sound ratings as low as 72 dB. (See page 3.)

Easy to service cabinets

provide easy single--panel accessibility

to serviceable components during maintenance and installation.

The basepan, with integrated drain pan, provides easy ground

level installation with or without a mounting pad. Convenient

Содержание 704C EVOLUTION

Страница 1: ...iency Each compressor is hermetically sealed against contamination to help promote longer life and dependable operation Vibration isolation provides quiet operation Compressors have internal high pres...

Страница 2: ...ch keeps the conditioned air from being affected by the outdoor ambient temperature and provides improved indoor air quality Conforms to American Society of Heating Refrigeration and Air Conditioning...

Страница 3: ...A SEER Sound Ratings dBA 024 2 800 24 000 11 13 0 72 030 2 1 2 1000 28 800 11 13 0 72 036 3 1200 36 000 11 13 0 74 042 3 1 2 1400 41 000 11 13 0 74 048 4 1600 45 000 11 13 0 78 060 5 1750 57 000 11 1...

Страница 4: ...fficiency 700 875 1050 1225 1400 1750 Max 800 1000 1200 1400 1600 2000 Size in 10x10 10x10 11x10 11x10 11x10 11x10 Motor HP RPM 1 2 1 2 3 4 3 4 3 4 1 HIGH PRESSURE SWITCH psig 650 15 420 25 Cutout Res...

Страница 5: ...m s variable speed indoor blower delivers Bryant s patented PerfectHumidity technology that allows for even greater humidity control Along with more precisely controlling temperature and humidity the...

Страница 6: ...FILTER RACK EVAPORATOR COIL TOP FILTER RACK BEND FLANGE AT 90 SCREW TO DIVIDER WITH 1 IN SCREW BOTTOM FILTER RACK MANUAL OUTSIDE AIR DAMPER DAMPER BLADE MANUAL OUTSIDE AIR HOOD REPLACEMENT PANEL 704C...

Страница 7: ...7 A06120 704C024 036 Unit Dimensions 704C...

Страница 8: ...8 A06121 704C042 060 Unit Dimensions 704C...

Страница 9: ...G E F G D E A05308 UNIT SIZE ODS CATALOG NUMBER A IN MM B IN MM C IN MM D IN MM E IN MM F IN MM G IN MM 704C024 036 CPRFCURB006A00 8 203 11 279 16 1 2 419 28 3 4 730 30 3 8 771 44 5 16 1126 45 15 16 1...

Страница 10: ...ased on required cooling capacity Enter Net Cooling Capacities table at condenser entering temperature of 95 F The 036 unit at 1200 cfm and 67 F ewb entering wet bulb will provide a total capacity of...

Страница 11: ...21 1 17 8 18 0 19 4 21 4 SHC 17 8 17 0 14 5 11 7 18 5 18 1 15 5 12 3 kW 2 8 2 8 3 0 3 0 2 9 2 9 3 0 3 0 Cooling Extended Performance Table 704C030 Temp F Outdoor Air Entering Condenser Evaporator Air...

Страница 12: ...8 5 31 5 28 1 27 2 29 3 32 3 SHC 26 2 20 9 21 9 17 1 27 8 23 5 24 7 18 9 kW 4 2 4 3 4 3 4 3 4 4 4 4 4 4 4 4 Cooling Extended Performance Table 704C042 Temp F Outdoor Air Entering Condenser Evaporator...

Страница 13: ...5 3 38 8 34 6 33 3 35 9 39 5 SHC 32 4 27 0 28 4 21 9 34 1 28 9 30 6 23 3 kW 5 5 5 4 5 5 5 5 5 5 5 5 5 5 5 5 Cooling Extended Performance Table 704C060 Temp F Outdoor Air Entering Condenser Evaporator...

Страница 14: ...ES 1 Ratings are net they account for the effects of the evaporator fan motor power and heat 2 Direct interpolation is permissible Do not extrapolate 3 The following formulas may be used Sensible capa...

Страница 15: ...IR FLEXIBLE DUCT CEILING CONCENTRIC DIFFUSER BOX FIELD SUPPLIED SUPPLY AIR FLEXIBLE DUCT ROOF MOUNTING CURB C00023 USER INTERFACE DISCONNECT PER NEC FROM POWER SOURCE RETURN AIR TOP COVER FROM GAS LIN...

Страница 16: ...nflow openings Remove theinsertssimilar toremoving anelectrical knockout Leave onduct covers to seal the horizontal discharge openings in the unit Units installed in horizontal discharge orientation d...

Страница 17: ...6 60 6 60 70 11 3 15 0 54 2 62 5 76 2 86 6 80 90 15 0 20 0 72 2 83 3 98 8 112 7 100 125 208 230 3 60 187 253 15 4 88 0 0 8 6 8 26 9 26 9 35 35 3 8 5 0 10 4 12 0 26 9 26 9 30 35 7 5 10 0 20 8 24 1 34...

Страница 18: ...a phase imbalance in supply volt age is greater than 2 Use the following formula to determine the percentage of voltage imbalance Voltage imbalance max voltage deviation from average voltage 100 x av...

Страница 19: ...19 TYPICAL WIRING SCHEMATIC 230 1 60 7 0 A06126 704C...

Страница 20: ...20 TYPICAL WIRING SCHEMATIC 230 3 60 5 0 A06127 704C...

Страница 21: ...capacity as defined by unit size Actual airflow request will be adjusted from nominal using indoor and outdoor temperature and indoor humidity data to optimize the system operation for occupant comfo...

Страница 22: ...ation capableof beingwiped clean Aluminum foil faced fiberglass insulation shall be used in the entire indoor air cavity seciton 5 Unit shall have a field supplied condensate trap C Fans 1 The indoor...

Страница 23: ...tion whichshallallow unitto operatedown to0 F outdoorambi ent temperature in cooling 6 Filter Rack Kit Shall provide filter mounting for downflow and horizontal applications 7 Square To Round Duct Tra...

Страница 24: ...e or change at any time specifications or designs without notice and without incurring obligations E2006 Bryant Heating Cooling Systems 7310 W Morris St Indianapolis IN 46231 Printed in U S A Edition...

Отзывы: